Rosemount Raptor<br />

System Configuration Manual<br />

300510EN, Rev AA<br />

December 2010<br />

5.8.3 Temperature Sensor Configuration<br />

The 2240S MTT Temperature Sensor tab lets you configure a sensor<br />

connected to the Rosemount 2240S Multi-input Temperature Transmitter.<br />

The 2240S MTT Temperature Sensor tab input fields are disabled in case no<br />

2240S Multi-input Temperature Transmitter is connected to the Tankbus. In<br />

that case, no 2240S temperature transmitter will be mapped to the 2410 tank<br />

database.<br />

To configure the temperature sensors for a Rosemount 2240S, do the<br />

following:<br />

1. In the 22xx ATD window select the 2240S MTT Temperature Sensor tab:<br />

2. The Rosemount 2240S is equipped with a DIP switch that automatically<br />

configures the 2240S for a certain kind of temperature element and<br />

wiring. By selecting the Use Auto Sensor Configuration check box, the<br />

2240S transmitter is automatically configured according to the DIP<br />

switch settings. See the Rosemount 2240S Multi-Input Temperature<br />

Transmitter Reference Manual (Document No. 300550EN) for more<br />

information.<br />

In case a temperature element type is used that does not match the Auto<br />

Sensor Configuration, the 2240S transmitter can be <strong>manual</strong>ly configured<br />

as described below.<br />

5-68 Section 5. Installing a Raptor Level Gauging System