Rosemount Raptor<br />

System Configuration Manual<br />

300510EN, Rev AA<br />

December 2010<br />

5.7.3 Advanced<br />

Configuration<br />

In addition to the basic configuration, there are advanced configuration<br />

options available for the Rosemount 5900S Radar Level Gauge. These may<br />

be used to optimize measurement performance for certain applications.<br />

Tank Shape<br />

The Tank Type and Tank Bottom Type parameters optimize the Rosemount<br />

5900S for various tank geometries and for measurements close to the tank<br />

bottom.<br />

To configure the 5900S Radar Level Gauge for a certain tank shape, do the<br />

following:<br />

1. In the 5900S RLG Properties window select the Tank Shape tab:<br />

2. Select a Tank Type option that matches the actual tank. Choose<br />

Unknown if there is no option that is applicable.<br />

3. Select Tank Bottom Type that matches the actual tank. Choose<br />

Unknown if there is no option that is applicable.<br />

4. Click the OK button to save the configuration and close the window.<br />