Rosemount Raptor<br />

System Configuration Manual<br />

300510EN, Rev AA<br />

December 2010<br />

5.9.2 Installing a 5400<br />

Using the<br />

Installation<br />

Wizard<br />

The installation wizard in TankMaster WinSetup is a tool that may be used to<br />

install and configure a Rosemount 5400 Radar Level Transmitter and other<br />

devices.<br />

However, in most cases the following procedure is recommended when<br />

installing a new Rosemount 5400 transmitter:<br />

1. Configure the Rosemount 2160 FCU Slave Database by including the<br />

new 5400 transmitter. Ensure that the correct Modbus address is<br />

configured (see “Installing a Rosemount 2160 FCU” on page 5-25 for<br />

more information).<br />

2. Configure the Rosemount 2410 Tank Database in the 2410 Tank Hub<br />

Properties/Tank Database window, (see “Installing a Rosemount 2410<br />

Tank Hub” on page 5-38 for more information).<br />

3. Install the 5400 in TankMaster via the 2410 Tank Hub Properties/Device<br />

Tags window.<br />

4. Configure the 5400 (see “Configuration via 5400 Properties” on<br />

page 5-79).<br />

See also “Adding a Tank to a Raptor System” on page 5-114 for further<br />

information on adding tanks and devices to a Raptor system.<br />

In case the recommended installation procedure as described above can not<br />

be used, the installation wizard offers an alternative method to install a new<br />

Rosemount 5400 Radar Level Transmitter in TankMaster. In this case do the<br />

following:<br />

1. Configure the Rosemount 2160 FCU Slave Database by including the<br />

new 5400 transmitter. Ensure that the right Modbus address is<br />

configured (see “Installing a Rosemount 2160 FCU” on page 5-25 for<br />

more information).<br />

2. Configure the Rosemount 2410 Tank Database in the<br />

2410 Tank Hub Properties/Tank Database window, (see “Installing a<br />

Rosemount 2410 Tank Hub” on page 5-38 for more information).<br />

3. Install and configure the Rosemount 5400 as described in “Using the<br />

installation wizard” on page 5-85.<br />