29.12.2016 Views

emerson-300510en-users-manual

Emerson Tank Gauging System

Emerson Tank Gauging System

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

System Configuration Manual<br />

300510EN, Rev AA<br />

December 2010<br />

Rosemount Raptor<br />

2410 Tank Hub<br />

See the Rosemount 2410 Tank Hub Reference Manual (Document no. 300530EN) for more information.<br />

Devices > Expand all Show all devices connected to the selected<br />

Rosemount 2410 Tank Hub.<br />

Collapse All Close the device folder.<br />

Uninstall<br />

Save<br />

Database to<br />

File<br />

Upload<br />

Database<br />

View Input<br />

Registers<br />

View Holding<br />

Registers<br />

View<br />

Diagnostic<br />

Registers<br />

Restart<br />

Logging<br />

Program<br />

Live List<br />

Manual Relay<br />

Control<br />

Simulation<br />

Properties<br />

Write Protect<br />

Remove the selected device.<br />

Save the current holding register setup to file. This<br />

function can be useful if you would like to save the<br />

current database as a backup. It can be<br />

downloaded to a device by choosing the Upload<br />

Database option.<br />

Upload a database to the selected device.<br />

View input register values. You can choose<br />

between a predefined set of registers or you can<br />

specify a certain range of registers.<br />

View holding (database) registers. You can choose<br />

between a predefined set of registers or you can<br />

specify a certain range of registers.<br />

View diagnostic registers for the selected device.<br />

Restart the device. The boot software performs an<br />

initialization procedure and memory tests.<br />

Log the diagnostic registers.<br />

Download an application program to the device.<br />

Show a list of devices connected to the Tankbus.<br />

Manually change relay status.<br />

Simulate field devices to verify communication with<br />

a host system.<br />

View and change the current device settings (not in<br />

View Only mode).<br />

Protect the holding register database from<br />

unintentional changes.<br />

Section 8. Menu Guide<br />

8-5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!