Rosemount Raptor<br />

System Configuration Manual<br />

300510EN, Rev AA<br />

December 2010<br />

10. In the 5900S RLG Properties window select the Geometry tab:<br />

11. Enter the tank geometry parameters:<br />

a. Tank Reference Height (R)<br />

The Tank Reference Height (R) is the distance from the hand dip<br />

nozzle (Tank Reference Point) to the Zero Level (Datum Plate) close<br />

to the bottom of the tank.<br />

b. Reference Distance (G)<br />

The Reference Distance (G) is the distance between the Tank<br />

Reference Point and the Gauge Reference Point, which is located at<br />

the upper surface of the nozzle flange or manhole cover on which<br />

the gauge is mounted.<br />

G is positive if the Tank Reference Point is located above the Gauge<br />

Reference Point, otherwise G is negative.<br />

Tank Reference<br />

Point<br />

G>0<br />

Gauge Reference<br />

Point<br />

G