5.1 SYSTEM CONFIGURATION OVERVIEW<br />

5.1.1 Preparations Before installing a Rosemount Tank Gauging system you should ensure that<br />

the following information is available:<br />

• A plan of all field devices and tanks.<br />

• Unit IDs of each device (Unit ID is a unique identifier given to each<br />

Raptor device at factory).<br />

• Modbus addresses of level devices and ATD devices. The Raptor<br />

devices are shipped with default addresses which will be changed at<br />

system configuration. The Modbus addresses are configured in the<br />

Slave Database of the 2160 FCU and the Tank Database of the 2410<br />

Tank Hub as described below.<br />

• Tank geometry parameters and reference distances such as tank<br />

reference height (R) and distance between Zero level (datum plate)<br />

and tank bottom.<br />

• Antenna types used for the various level gauges.<br />

5.1.2 Installation<br />

Procedure<br />

Installation and configuration of a Rosemount Raptor level gauging system<br />

includes the following steps as briefly described below:<br />

1 Communication Protocol Setup<br />

Specify communication protocol parameters:<br />

• The Modbus Master Protocol handles communication between a<br />

TankMaster work station and field devices such as the Rosemount<br />

2160 Field Communication Unit and the Rosemount 2410 Tank Hub.<br />

• The Slave Protocol handles communication with a host computer.<br />

• Communication with TankMaster can be supervised by logging various<br />

error types and function codes.<br />

2 Preferences<br />

Specify measurement units, tag prefixes for tank and device labels,<br />

inventory parameters, and parameters to be displayed when viewing tank<br />

data.<br />

3 Installation and Configuration of 2160 Field Communication Unit<br />

The Rosemount 2160 Field Communication Unit (FCU) has to be installed<br />

and configured prior to installing other devices such as a Rosemount 2410<br />

Tank Hub and a Rosemount 5900S Radar Level Gauge.<br />

To install a Rosemount 2160 FCU:<br />

• Assign a Modbus communication address<br />

• For each communication port, configure protocol and appropriate<br />

communication parameters<br />

• Configure the Slave Database with information about the devices<br />

connected to the fieldbus<br />

5-2 Section 5. Installing a Raptor Level Gauging System