System Configuration Manual<br />

300510EN, Rev AA<br />

December 2010<br />

Rosemount Raptor<br />

Example 2: several Tanks connected to one 2410 Tank Hub<br />

This example includes three tanks, each of which has one Rosemount 5400<br />

Radar Level Transmitter and one Rosemount 2240S Multi-input Temperature<br />

Transmitter. All tanks are connected via the Tankbus to the same Rosemount<br />

2410 Tank Hub. The 2410 Tank Hub is connected to a TankMaster PC via a<br />

2160 Field Communication Unit.<br />

For each tank the Modbus addresses of the 5400 and other devices have to<br />

be entered in both the 2160 FCU Slave Database and the 2410 Tank<br />

Database.<br />

The 2240S and other non-level devices are handled as a single ATD device.<br />

In this example the 2410 Tank Hub serves three tanks. For Tank Position 1 in<br />

the 2410 Tank Database the ATD Modbus address is automatically set equal<br />

to the Modbus address of the 2410 Tank Hub itself. See “Tank Database<br />

Setup” on page 5-42 for further information.<br />

The Modbus address configuration is summarized in Table 5-3 below:<br />

Table 5-3. Configuration of the<br />

2160 FCU Slave Database and<br />

the 2410 Tank Database for<br />

three tanks and one 2410 Tank<br />

Hub<br />

Modbus Address<br />

Tank 5400 Level Transmitter ATD (2230, 2240S ) 2410 Tank Hub<br />

TK-1 1 101 101<br />

TK-2 2 102 - " -<br />

TK-3 3 103 - " -<br />

Figure 5-6. Configuration<br />

example with one 2410 Tank<br />

Hub and many tanks<br />

2160 FCU<br />

2240S<br />

2410<br />

2230<br />

5400<br />

TK-1<br />

2230<br />

5400<br />

2240S<br />

2240S<br />

TK-2<br />

2230<br />

5400<br />

TK-3<br />

The 2410 Level addresses in the 2160 FCU Slave Database must be equal to<br />

the Level Modbus addresses in the 2410 Tank Database.<br />

In this example the Level Modbus addresses of the three tanks are entered in<br />

positions 1A, 2A, and 3A in the 2160 FCU Slave Database and in tank<br />

positions 1, 2, and 3 in the 2410 Tank Database as illustrated in Figure 5-7:<br />

Section 5. Installing a Raptor Level Gauging System<br />

5-35