process<strong>in</strong>g variables on the adhesion strength <strong>of</strong> substrates bonded with these PSAs - the results <strong>of</strong><br />

which are reported <strong>in</strong> this paper.<br />

O<br />

HO OH<br />

P<br />

O<br />

( CH2)7 CH CH CH2 CH CH CH2<br />

(I)<br />

Prepolymer <strong>of</strong> PCNSL<br />

Materials & Methods<br />

(<br />

CH CH2 )<br />

n<br />

n = 2 to 4<br />

Polychloroprene rubber (CR) (Skyprene Y-30H, Toyo Soda Co.) was supplied by M/s. Jeni<br />

Polyplast, Ahmedabad, Gujarat, India. CNSL conform<strong>in</strong>g to Indian Standards IS: 840 - 1964 was<br />

supplied by M/s. Adarsh Industrial Chemicals, Sanoor, Mangalore, India. Commercial sample <strong>of</strong> PSA<br />

(Fevicol SR 998) was manufactured by M/s. Pidilite Industries Pvt. Ltd., Mumbai, India.<br />

PCNSL was synthesized (at 20 kg level) by the simultaneous esterification and oligomerization <strong>of</strong><br />

CNSL us<strong>in</strong>g o-phosphoric acid at controlled temperature, time and vacuum conditions <strong>in</strong> a Multi<br />

Purpose Reactor (Pyrodevices) supplied by M/s. Thermosystems, Veli, Thiruvananthapuram.<br />

Blends <strong>of</strong> NR, CR and PCNSL (<strong>in</strong> various proportions) were prepared by mix<strong>in</strong>g on an open two<br />

roll mill (6” X 12”) for 5 m<strong>in</strong>utes followed by homogenization and sheet<strong>in</strong>g out. The sheets were cut<br />

to small pieces and weighed amounts <strong>of</strong> the same were kept immersed <strong>in</strong> requisite amount <strong>of</strong><br />

dichloromethane for 24 h, stirred there-after for homogeneity and kept <strong>in</strong> air-tight conta<strong>in</strong>ers.<br />

The viscosity <strong>of</strong> the PSAs was measured on a rheometer (Anton Paar Physica, Austria, model<br />

MCR-150) by parallel plate method, at 28°C over the shear rate range from 0.1 s 1 to 100 s 1 . T-peel<br />

test specimens were prepared from rex<strong>in</strong> sheet cut to size (75 mm X 25 mm). Two coats <strong>of</strong> the PSA<br />

were applied manually on an area <strong>of</strong> 50 mm X 25 mm from one end <strong>of</strong> the fabric surface, an open<br />

tack time <strong>of</strong> 2 m<strong>in</strong>utes was given and bonded together under hand pressure. The test specimens were<br />

kept pressed between two flat sheets under a load <strong>of</strong> 10 kg, applied uniformly for a period <strong>of</strong> 24 h or<br />

168 h. The T-peel adhesion strength <strong>of</strong> the specimens was measured on a Universal Tensile <strong>test<strong>in</strong>g</strong><br />

Mach<strong>in</strong>e (Hounsfield, H5KS) at a cross head speed <strong>of</strong> 100 mm/m<strong>in</strong>. The optical micro photographs<br />

<strong>of</strong> the failure surfaces were obta<strong>in</strong>ed us<strong>in</strong>g a stereo microscope (Leica MZ 16A / DC Twa<strong>in</strong>) at a<br />

magnification <strong>of</strong> X 11.<br />

RESULTS AND DISCUSSION<br />

Effect <strong>of</strong> type <strong>of</strong> PCNSL and storage time <strong>of</strong> bonded specimens on adhesion strength<br />

The results on T-peel strength <strong>of</strong> rex<strong>in</strong> specimens bonded with the PCNSL based PSAs are given<br />

<strong>in</strong> Table 1. It shows a general <strong>in</strong>crease <strong>in</strong> the T-peel strength with the change <strong>in</strong> type <strong>of</strong> PCNSL from<br />

2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!