Step(b)

Find lever arm z. From Fig. 4.6-1(b),

Hence

concrete compression = 0.405fcuhx

lever arm z = d - 0.45x

Hence

z = 700 - 0.45x = 649 mm

Step(c)

Find A •. From Fig. 4.6-1(b),

Designing from first principles 109

M = 0.405fcuhx(d -

0.45x)

(300)(10 6 ) = (0.405)(40)(250)(x)(700 - 0.45x)

x 2 - 1560x + 165000 = 0

·M = 0.87/yAsz

x =114m

(or 1441 mm, which is inadmissible)

(where z = 649 mm from Step (b) above)

(300)(10 6 ) = (0.87)(460)A.(649)

As= 1155 mm 2

Provide four 20 mm bars (As = 1257 mm 2 )

Comment

Example 4.5-3 solves the same problem using BS 8110's design chart. See

also Example 4.6-5 which follows the I.Struct.E. Manual's procedure [14].

Example 4.6-4

Repeat Example 4.6-3 if M is 900 kNm. What is that xld ratio of the beam

section so designed?

SOLUTION

Step(a)

Check concrete capacity Mu·

Mu = 764.4 kNm (from Step (a) of Example 4.6-3)

Since M > Mu, compression steel is required.

Sup(b)

Find compression steel area A~. From eqn (4.6-6),

0.87/yA~(d - d') = M - Mu

(0.87)(460)A~(700 - 60 say) = (900 - 764.4)(10 6 )

A~= 530 mm 2