348 Prestressed concrete simple beams

Fig. 9.3-l

Lower limit for service condition

Lower limit for stresses at transfer

Hence, from eqns (9.3-5) and (9.3-6),

~ + ~s :S 21.82

P- Pes> -3 89

A Zz- .

With P = 1046 kN and A, Z 1 and Z 2 as in Example 9.2-2, we have e 5 :S

238 mm from the first condition (and, less critically, e 5 :S 262 mm from the

second).

Similarly, the reader should verify that, at transfer,

es :S 233 mm at 3 m from support

es :S 217 mm at 1 m from support

es :S 205 mm at support

Figure 9. 3-1 shows the permissible tendon zone which satisfies the stress

conditions both in service and at transfer. To increase the depth of the zone

at midspan, a lower effective prestressing force than Pe = 837 kN has to be

used.

9.4 Loss of prestress

Design calculations for the loss of prestress are usually straightforward;

simple practical procedures are given in BS 8110: Clauses 4.8 and 4.9.

In general, allowance should be made for losses of prestress resulting

from:

(a)

(b)

Relaxation of the steel comprising the tendons: Typically this

produces a loss of about 5%.

Elastic deformation of the concrete: In a pre-tensioned beam there is

an immediate loss of prestress at transfer, resulting from the elastic

shortening of the beam. In post-tensioning, the elastic shortening of

the concrete occurs when the tendons are actually being tensioned;