27.06.2021 Views

F. K. Kong MA, MSc, PhD, CEng, FICE, FIStructE, R. H. Evans CBE, DSc, D ès Sc, DTech, PhD, CEng, FICE, FIMechE, FIStructE (auth.)-Reinforced and Prestressed Concrete-Springer US (1987)

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

290 Eccentrically loaded columns and slender columns

N 2 - N(Ny + NE(1 + q)) + NENy = 0

where N is the load at material failure of the column; Ny is the squash

load ( = area x yield strength; NE is the Euler load ( = n 2 Elll 2 ); 17 is a

function of the slenderness ratio 1/r, and values of 0.003 (1/r) and 0.3

(l/100r) 2 have been used for 17 in practical design.

It is interesting to compare the steelwork designers' Perry-

Robertson formula with the reinforced concrete designers' eqn

(7.4-6), and observe that both formulae are primarily concerned

with material failure and that, in each formula, the load capacity N is

regarded as being significantly dependent on the column slenderness.

7.8 BS 8110: Part 3 gives a comprehensive set of column design charts,

one of which is reproduced as Fig. 7 .3-1. It can be seen that each of BS

8110's interaction curves refers to a particular set of (e;fcu;fy; dlh) values,

where (! is the steel ratio Asclbh.

The I.Struct.E. Manual (5), on the other hand, uses only two variables

((!/yl/cu; d/h), with the great advantage that only a very small number of

charts are then necessary for design. Explain whether the I.Struct.E.

Manual (5) is justified in using only two variables (!/yl/cu and d/h.

Ans.

In Section 7.1, the authors use three variables: (elfcu;fy and d/h).

Theoretically, it is impossible to use only two variables

((!/yl/cu; d/h). For a detailed explanation, see Example 7.1-7.

References

1 ACI Committee 318. Commentary on Building Code Requirements for

Reinforced Concrete (ACI 318R-83). American Concrete Institute, Detroit,

1983.

2 Nawy, E. G. Columns in uniaxial and biaxial bending. In Handbook of

Structural Concrete, edited by Kong, F. K., Evans, R. H., Cohen, E. and Roll,

F. Pitman, London, and McGraw-Hill, New York, 1983, Chapter 12, Sections

2.5 and 2.6.

3 ACI-ASCE Committee 441. Reinforced Concrete Columns (ACI Publication

SP-50). American Concrete Institute, Detroit, 1975.

4 Evans, R. H. and Lawson, K. T. Tests on eccentrically loaded columns with

square twisted steel reinforcement. The Structural Engineer, 35, No. 9, Sept.

1957' pp. 340-8.

5 I.Struct.E./ICE Joint Committee. Manual for the Design of Reinforced

Concrete Building Structures. Institution of Structural Engineers, London,

1985.

6 Coates, R. C., Coutie, M. G. and Kong, F. K. Structural Analysis, 3rd edn.

Van Nostrand Reinhold, Wokingham, 1988, pp. 304-11 and 326.

7 Smith, I. A. Column design to CP110. Concrete, 8, Oct. 1974, pp. 38-40.

8 Bresler, B. Design criteria for reinforced concrete columns under axial load

and biaxial bending. Proc. ACI, 57, No. 5, Nov. 1960, pp. 481-90.

9 Furlong, R. W. Ultimate strength of square columns under biaxially eccentric

loads. Proc. ACI, 51, No. 9, March 1961, pp. 1129-40.

10 CP 110: 1972. Code of Practice for the Structural Use of Concrete. British

Standards Institution, London, 1972.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!