Design and detailing-illustrative examples 439

M = 40% of 307 kNm (Fig. 11.5-5: Case 2)

= 123 kNm

M (123)(10 6 )

fcubd 2 = (40)(350)(500Z) = 0.03S

From Table 4.7-2,

z

d = 0.94

X

d = 0.13

< K' of Table 4.7-1

From eqn (4.7-9),

M (123)(10 6 )

As = 0.87/yz = (0.87)(460)(0.94)(500)

= 654 mm 2 2T25 U-bars (982 mm 2 )

From Table 4.10-2

ultimate anchorage bond length = 32(j) = 800 mm

Using eqns (6.6-3(a) (b)),

required anchorage length = ~~i (800) = 533 mm 2

The curtailment diagram for the longitudinal reinforcement is shown in

Fig. 11.5-10, which should be read in conjunction with the reinforcement

details in Fig. 11.5-12 (seep. 444).

Step 6 Shear reinforcement

For further explanations of the calculations, see Comments on Step 6 at

the end.

(a)

From Fig. 11.5-12, the minimum tension reinforcement along the

beam may reasonably be taken as 2T25, i.e. As= 982 mm 2 •

100As _ (100)(982) = O 56

bvd - (350)(500) ·

From Table 6.4-1,

Vc = 0.61 N/mm 2

(b) Minimum links (see Section 6.4: 'Shear resistance in design

calculations: Step 4') will be provided where v :s: (vc + 0.4), i.e.

where V :S: (vc + 0.4)bvd.

V :s: (0.61 + 0.4)(350)(500) N

= 177 kN