ChangeParametersMultipleElement Sample Code<br />

Borland® Delphi<br />

Var ParamList, ValueList : OLEVariant<br />

// Set ParamList up to modify the MW output of generators<br />

ParamList := VarArrayCreate([1,3], varOleStr);<br />

ParamList[1] := 'BusNum';<br />

ParamList[2] := 'GenID';<br />

ParamList[3] := ‘GenMW’;<br />

// ValueList is setup with MW values for generators at buses 1 and 2<br />

ValueList := VarArrayCreate([1,2], varOleStr);<br />

For k := 1 to 2 do begin<br />

IndValueList := VarArrayCreate([1,3], varOleStr);<br />

IndValueList[1] := k;<br />

IndValueList[2] := ‘1’;<br />

IndValueList[3] := k*10;<br />

ValueList[k] := IndValueList;<br />

End;<br />

// Make the ChangeParametersMultipleElement call<br />

Output = SimAuto.ChangeParametersMultipleElement('Sim_Solution_Options', _<br />

ParamList, ValueList)<br />

Microsoft® Visual Basic for Applications<br />

' Set ParamList up to modify the MW output of generators<br />

Dim ParamList As Variant<br />

ParamList = Array("BusNum", "GenID", "GenMW")<br />

' ValueList is setup with MW values for generators at buses 1 and 2<br />

Dim ValueList(2) As Variant<br />

For k = 0 to 1<br />

Dim IndValueList As Variant<br />

IndValueList = Array(k+1,"1",(k+1)*10)<br />

ValueList(k) = IndValueList<br />

Next<br />

' Make the ChangeParametersMultipleElement call<br />

©2011 <strong>PowerWorld</strong> Corporation<br />