[GEN busnum id], [GEN "name_nomkv" id], [GEN "buslabel" id], [GEN "label"]<br />

[LOAD busnum id], [LOAD "name_nomkv" id], [LOAD "buslabel" id], [LOAD "label"]<br />

[BRANCH busnum1 busnum2 ckt], [BRANCH "name_kv1" "name_kv2" ckt],<br />

[BRANCH "buslabel1" "buslabel2" ckt], [BRANCH "label"]<br />

[SHUNT busnum id], [SHUNT "name_nomkv" id], [SHUNT "buslabel" id], [SHUNT "label"]<br />

[destination parameters]: These parameters have different meanings depending on object<br />

type of the element. Bus numbers must be used here.<br />

GEN: [busnum id]<br />

LOAD: [busnum id]<br />

BRANCH: [busnum1 busnum2 id]<br />

SHUNT: [busnum id]<br />

percentage: The percentage of the device to move to the new destination. This is only valid for<br />

generators and loads, and allows partial generation or load to be moved to the new location.<br />

Combine([elementA], [elementB]);<br />

NOTE: THIS ACTION IS ONLY AVAILABLE FOR GENERATORS.<br />

Use this action to combine two generators, two loads, or two transmission line. Note that elementA<br />

and elementB must be of the same object type. You can not combine a BRANCH and a LOAD.<br />

[elementA]: The object that should be moved. Must be one of the following formats.<br />

[GEN busnum id]<br />

[LOAD busnum id]<br />

[BRANCH busnum1 busnum2 ckt]<br />

[elementB]: The object that element A should be combined with. Must the same format as for<br />

elementA.<br />

SplitBus([element], NewBusNumber, InsertBusTieLine, LineOpen);<br />

Use this action to transform one bus into two connected buses.<br />

[element]: The bus that should be split. Must be of the following format:<br />

[BUS num]<br />

[BUS "name_nomkv"]<br />

[BUS "buslabel"]<br />

NewBusNumber: The number of the new bus resulting from the split. Must be unique, that is,<br />

it cannot be a number that identifies another number in the case.<br />

InsertBusTieLine Set to YES or NO. YES means to insert a very low-impedance bus tie<br />

between the bus to split and its offspring. The new branch will have an impedance of 0.0000 +<br />

j0.0001 ohms. NO means that no bus tie will be inserted. If this parameter is not specified, then<br />

YES is assumed.<br />

LineOpen Set to YES or NO. YES means that the bus tie should be inserted as an open branch.<br />

NO means that the bus tie will be inserted as a closed branch. This options is valid only if<br />

InsertBusTieLine is set to YES. If this parameter is not specified, then NO is assumed.<br />

MergeBuses([element], filter);<br />