This area deals with lines used as ties between breakers. These lines are modeled as zero<br />

impedance connections. The identification of a branch as a bus tie depends on the value specified as<br />

the Maximum P.U. Impedance for Bus Ties. Branches with total P.U. impedance below this<br />

value will be considered bus ties when auto-inserted.<br />

In this area two choices are given for how to insert the bus tie breakers: Do not insert stubs for<br />

bus ties and Only insert a single circuit breaker. The first choice allows you to decide if line<br />

stubs will be drawn when the tie breaker is inserted. The second sets whether or not only one circuit<br />

breaker is inserted on the tie breaker. This could be useful for determining real lines from bus tie<br />

breakers.<br />

©2011 <strong>PowerWorld</strong> Corporation<br />