Automatically Inserting Transmission Lines<br />

The Automatic Insertion of Lines/Transformers Dialog is used to automatically draw transmission lines<br />

and transformers on the oneline diagram between existing bus display objects. Only branches that are<br />

already defined in the power flow case can be added automatically; if you need to define a brand new<br />

branch, see Transmission Line Display Objects. Thus, this option is useful only when you are starting<br />

with an existing power flow case, not building a case from scratch.<br />

To insert lines and transformers automatically, you must first have drawn the buses for each end of<br />

the device. <strong>Simulator</strong> then draws the branch display objects connecting the buses for each<br />

transmission line/transformer in the power flow case not already shown on the oneline.<br />

To display the dialog, in the Edit Mode go to the Draw ribbon tab and choose Auto Insert > Lines on<br />

the Quick Insert ribbon group.<br />

The dialog has the following options:<br />

Minimum kV Level<br />

<strong>Simulator</strong> will automatically draw line and transformer display objects between terminals whose<br />

nominal voltages meet or exceed the minimum kV level specified in this field. For a branch object to<br />

be drawn, either one of its terminals must satisfy this criterion. This option is useful for suppressing<br />

the automatic addition of generator step-up transformers if that kind of detail is not warranted.<br />

Default Drawing Values<br />

This button opens the Default Drawing Values Dialog. Options such as the automatic insertion of<br />

transmission line stubs, text fields, circuit breakers, and pie charts are specified in the Default<br />

Drawing Values Dialog.<br />

Insert Text Fields<br />

If this box is checked, the default fields associated with the transmission line will appear around the<br />

transmission line.<br />

Insert Equivalenced Objects<br />

If this option is checked, equivalenced objects modeled as lines will also be automatically inserted<br />

with the real transmission lines.<br />

Use Only Selected Buses<br />

Instead of having <strong>Simulator</strong> automatically insert line and transformer display objects throughout the<br />

oneline diagram, you can force it to insert the new objects only between the bus display objects that<br />

are currently selected. This option is enabled only when two or more bus display objects are<br />

currently selected on the oneline.<br />

Insert Pie Chart for Lines with No Limit and Bus Ties<br />

If this option is checked, <strong>Simulator</strong> will add pie chart objects to the lines that have no given limit or<br />

are bus ties as they are auto-inserted. Typically if a line is a bus tie or has no given limit, it is<br />

meaningless to include a pie chart on the element, since no relevant information about the<br />

transmission element can be gained from the pie chart object.<br />

Insert Multi Section Lines<br />

Check this option if you wish for <strong>Simulator</strong> to automatically insert lines designated as multi-section<br />

lines as well.<br />