Bus Display<br />

The Bus Display presents data describing each bus in the case. The Bus Display is a class of Case<br />

Information Display and therefore can be used in a manner consistent with all other case information<br />

displays. It has a case information toolbar from which you can print, copy, and modify its records as<br />

well as view the information dialog of its associated bus. You can also sort the bus records by clicking<br />

on the heading of the field by which you want to sort. Additionally, you can choose to restrict the<br />

records shown by the Bus Records Display according to the constraints of the area/zone/owner filters.<br />

Finally, when <strong>Simulator</strong> is in Edit Mode, the case information toolbar allows you to add new buses to or<br />

remove existing buses from the system.<br />

To show the bus records display, select Network > Buses from the Model Explorer or from the Case<br />

Information ribbon group under the Case Information ribbon tab.<br />

By default, the bus records display contains the following fields:<br />

Number and Name<br />

Bus number between 1 and 2,147,483,647 (equals 2^31 minus 1), and its alphanumeric identifier.<br />

Area Name<br />

Alphanumeric identifier of the bus’ area.<br />

Nom kV<br />

The nominal base voltage of the bus in kV.<br />

PU Volt<br />

Bus’ per unit voltage magnitude.<br />

Volt (kV)<br />

Bus’ actual voltage magnitude in kV. This is the per unit voltage magnitude multiplied by the bus’<br />

nominal voltage.<br />

Angle (Deg)<br />

Bus’ voltage angle in degrees.<br />

Load MW, Load Mvar<br />

Total real and reactive load at the bus. If no loads are located at the bus, these fields are blank.<br />

Gen MW, Gen Mvar<br />

Total real and reactive generation at the bus. If no generators are located at the bus, these fields<br />

are blank.<br />

Switched Shunt Mvar<br />

Total switched shunt device reactive power injection at the bus.<br />

Act G Shunt MW, Act B Shunt Mvar<br />

Total real and reactive fixed bus shunt injections.<br />

Area Num<br />

The area number in which the bus is located.<br />

Zone Num<br />

The zone number in which the bus is located.<br />

©2011 <strong>PowerWorld</strong> Corporation<br />