Event Time<br />

Specify the time in seconds at which the event occurs.<br />

Event Type, Event Parameters<br />

The type of event and parameters will change depending on the Object Type chosen. Valid options<br />

are:<br />

Bus<br />

Apply Fault<br />

Apply the specified fault type.<br />

Fault Type - Balanced 3 Phase, Single Line to Ground, Line to Line, or Double Line to Ground<br />

Fault Across - Solid, with Impedance and specifying PU Resistance and PU Reactance,<br />

or with Admittance specifying PU Conductance and PU Susceptance<br />

Clear Fault<br />

Open<br />

Generator<br />

Load<br />

Open<br />

Close<br />

Clear a fault.<br />

Opens all AC lines connected to a bus.<br />

Open the generator.<br />

Close the generator.<br />

Ramp Values<br />

Ramp the output of the generator as defined by the Action Field. Options for the Action<br />

Field are MVA at Bus, Exciter Setpoint (Vref) and Governor Setpoint (Pref). Specify that the<br />

output be ramped By Value or Percentage. Specify the End Time in seconds at which the<br />

ramping stops.<br />

Set Values<br />

Set the output of the generator as defined by the Action Field. Options for the Action Field<br />

are MVA at Bus, Exciter Setpoint (Vref) and Governor Setpoint (Pref). Specify that the output<br />

be set By Value or Percentage.<br />

Open, Close<br />

Specify that the load either be opened or closed.<br />

Set Values<br />

Set the output of the generator as defined by the Action Field. Option for the Action Field is<br />

MW, Exciter Setpoint (Vref) and Governor Setpoint (Pref). Specify that the output be set By<br />

Value or Percentage.<br />

Switched Shunt<br />

Open, Close<br />

Specify that the load either be opened or closed.<br />

AC Line/Transformer<br />

Apply Fault<br />

Apply the specified fault type.<br />

©2011 <strong>PowerWorld</strong> Corporation<br />

1553