Flow Cycle List Display Results<br />

The Flow Cycle List has the following columns by default.<br />

Related Cycle Group<br />

Related Cycle Group Number will be the same for that which can be reached from one another.<br />

These cycles are likely related to one another.<br />

Area Names<br />

Comma delimited list of area names which are traversed by the cycle.<br />

Loss Mvar Reduction, Loss MW Reduction<br />

Estimate of the reduction in Mvar (or MW) losses in the entire cycle if the circulating flow is<br />

removed. The larger this number is, the more severe the circulating flow is. The list is sorted by<br />

the Loss Mvar Reduction by default.<br />

Cycle X-Weighted Average<br />

Shows the weighted average flow in the cycle weighted by the series reactance (X) values.<br />

Cycle Min Flow<br />

Shows the minimum flow on any branch in the cycle. The larger this number is, the more severe<br />

the circulating flow is.<br />

Lines in Cycle<br />

Number of lines (branches) in the cycle.<br />

Min Bus Num, Max Bus Num<br />

Shows the Minimum and Maximum bus number traversed in the cycle<br />

Min Tap Ratio, Max Tap Ratio<br />

Show the minimum and maximum tap ratio on any branch in the cycle.<br />

Max Percentage MVA Flow<br />