Add ability to define Custom String Expressions which represent the concatenation of<br />

strings from the columns of an object. Included in this is a new function available in the<br />

expression string with format "Str(x1, minlength, decimals)" where x1 represents a numeric<br />

variable, minlength represents the minimum number of characters for the result, and<br />

decimals represents the number of characters to the right of the decimal point.<br />

When choosing Send to Excel, <strong>Simulator</strong> will now programmatically set Excel to NOT "treat<br />

consecutive limiters as one". It also ensures that some "Other" character is not being used<br />

as a delimiter so that only TAB characters are used.<br />

Modified the editing of data in a case information displays (or through an AUX file) so that<br />

the string "&ModelExpressionName:8:4" can be entered. A string which starts with the<br />

character & will be treated as though the value of the named model expression is being<br />

entered in the field. The format of the string will be determine by the last two integer<br />

values representing the total number of digits and decimal places.<br />

The Transformer Configuration Field is now enterable and toggleable on a case information<br />

display.<br />

Modified case information displays show that when showing a value such as -0.01 which is<br />

truncated to fewer decimal places, the resulting string will still include the negative sign and<br />

show "-0.0" for example instead of "0.0".<br />

In a Custom String Expression, when using the Str(Value, Digits, Decimals) function, if the<br />

Decimals parameter is specified as negative, then it will truncate all trailing zeros beyond<br />

the decimal.<br />

Added fields for Owner records showing the Number of Branches by Type (Transformer,<br />

Line, SeriesCap, Breaker, Disconnect), and the number of switched shunts.<br />

Added fields for injection groups that list Area/Zone/Owner of all of the devices in the<br />

injection group. Fields are available for listing either the number or name of the associated<br />

Area/Zone/Owner.<br />

When sending Custom Case Information to Excel, only fields that are text will be marked as<br />

text. Previously, the formatting was based on columns being identified as text based fields<br />

instead of identifying each individual cell as to whether or not it is text.<br />

Added the ability with case information displays to show the Super Area in which a<br />

generators, loads, switched shunts, and branches are contained.<br />

Amps field is now available with loads.<br />

With buses and substation records, added the ability to specify latitude/longitude<br />

information using the four parameters of UTM longitude zone, UTM Easting, UTM Northing<br />

and specification of either north or south hemisphere.<br />

Contingency Analysis Enhancements<br />

Two different types of fields are now available with contingencies to list the<br />

Areas/Zones/Owners associated with the elements of the contingency. Fields exist for listing<br />

either the number or name of the associated Areas/Zones/Owners. Fields that are labeled<br />

with “recurse” will look inside injection groups, interfaces, and contingency blocks for<br />

identifying the associated Areas/Zones/Owners. Fields without “recurse” will not look inside<br />

injection groups, interfaces, or contingency blocks.<br />

Added option to use labels in contingency action descriptions. This includes actions shown<br />

in the Contingency Definition list and What Actually Occurred. This can be useful when used<br />

with a full-topology EMS model.<br />

When listing contingency results by element (bus, branch, interface, nomogram interface,<br />

or custom monitor), only those elements which actually have a violation are now listed<br />

Specific generators, loads, and switched shunts can now be specified in addition to buses<br />

when using Move, Set To, and Change By actions.<br />

Added an optional "inclusion filter" with each Contingency Global Actions Elements. The<br />

global action will only be used with a particular contingency only if the contingency meets<br />

the inclusion filter.<br />

©2011 <strong>PowerWorld</strong> Corporation<br />