ShowComplex : (optional) show complex form (MW+jMvar) (default=NO)<br />

AutoInsertSubStations(LocationSource, MapProjection, AutoInsertBranches,<br />

InsertIfNotAlreadyShown, “filename”, FileCoordinates);<br />

Use this action to automatically insert substations based on specified location data.<br />

LocationSource : “Bus”, “Substation” or “File”<br />

MapProjection : “Simple Conic”, “Mercator” or “x,y”<br />

AutoInsertBranches : YES to insert transmission lines when finished, NO not to<br />

InsertOnlyIfNotAlreadyShown : YES if only buses that are not already shown should be<br />

inserted, NO to insert all buses.<br />

“filename” : (optional) path to location source file (if LocationSource is “File”)<br />

FileCoordinates : (optional) format of coordinates in file “x,y” or “lon,lat” (if LocationSource is<br />

“File”)<br />

AutoInsertLineFlowPieCharts(MinkV, InsertOnlyIfNotAlreadyShown, InsertMSLines, Size);<br />

Use this action to automatically insert line flow pie charts.<br />

MinkV : Minimum kV level to insert (default=0)<br />

InsertOnlyIfNotAlreadyShown: (optional) if existing line flow objects are ignored<br />

(default=YES)<br />

InsertMSLines : (optional) insert pie charts for Multi-Section Lines (default=YES)<br />

Size : (optional) size (default=5.0)<br />

AutoInsertInterfaces(InsertPieCharts, PieChartSize)<br />

Use this action to automatically insert line flow objects.<br />

InsertPieCharts : (optional) Insert pie charts as well (default=YES)<br />

PieChartSize : (optional) default size of interface pie charts (default=50.0)<br />

ResetStubLocations(ZBRImpedance, NoStubsZBRs)<br />

Use this action to reset stub locations.<br />

ZBRImpedance : (optional) max P.U. impedance for bus ties (default=0.0001)<br />

NoStubsZBRs : (optional) Ignore stubs for bus ties (default=YES)<br />

General Script Commands<br />

The following script commands defined in the general Script section are available for display auxiliary<br />

files as well:<br />

ExitProgram<br />

LoadScript<br />

LoadData<br />

SelectAll<br />

UnSelectAll<br />

©2011 <strong>PowerWorld</strong> Corporation<br />