Data Gen<br />

BidCurve<br />

BidCurve subdata is used to define a piece-wise linear cost curve (or a bid curve). Each bid point<br />

consists of two real numbers on a single line of text: a MW output and then the respective bid (or<br />

marginal cost).<br />

Example:<br />

<br />

// MW Price[$/MWhr]<br />

100.00 10.6<br />

200.00 12.4<br />

400.00 15.7<br />

500.00 <strong>16</strong>.0<br />

<br />

ReactiveCapability<br />

Reactive Capability subdata is used to the reactive capability curve of the generator. Each line of text<br />

consists of three real numbers: a MW output, and then the respective Minimum MVAR and Maximum<br />

MVAR output.<br />

Example:<br />

<br />

// MW MinMVAR MaxMVAR<br />

100.00 -60.00 60.00<br />

200.00 -50.00 50.00<br />

400.00 -30.00 20.00<br />

500.00 -5.00 2.00<br />

<br />

Note: ReactiveCapability object types can also be directly created inside their own DATA section as<br />

well. Two of the key fields of the object are then the bus number and generator ID of the generator<br />

to which the ReactiveCapability point belongs.<br />