II) take into account all levels cumulatively (low confidence<br />

resource available includes both the high and medium<br />

confidence bands).<br />

Fig. 4. Maximum load capacity of potential wind farms (MW), given on<br />

NUTS III level.<br />

Calculated potential of wind units for electricity<br />

generation is technical and does not take into consideration<br />

TABLE I<br />

MAXIMUM LOAD CAPACITY OF POTENTIAL FACILITIES (MW)<br />

recent decision of the Croatian government to ban<br />

construction and planning of all new wind power plants<br />

(together with quarries, warehouses, factories etc.) on<br />

locations that are on islands and less than 1000 m from the<br />

sea (the projects that in the moment of the proclamation of<br />

the decree had already obtained the location permits are<br />

excluded). The act was explained as a measure of protection<br />

of Croatian coastal area. That unfortunately includes some<br />

of the best locations on Croatian islands and along the<br />

Adriatic coast.<br />

Despite good solar potential it is not likely that big solar<br />

power plants will be built in following years in Croatia due<br />

to high cost of these facilities (the graph representing RES<br />

cost – supply curve for 2010 shown on Fig. 7 does not<br />

contain data for big solar thermal power plants or PV due to<br />

high costs of such facilities that exceed chosen upper cost<br />

limit). Except certain number of households and other<br />

buildings that use PV systems, application of the<br />

photovoltaics will be reserved for isolated areas and specific<br />

purposes like telecommunication base stations,<br />

meteorological stations, lighthouses, road signs, public<br />

lightning, different autonomous monitoring systems<br />

(pollutant emission monitoring, forest fire protection,<br />

technical protection of individual facilities etc.).<br />

No County (NUTS III) Hydro Small hydro Windpower PV Biomass Geothermal<br />

I Zagrebačka 39.00 0.80 0 0.007 6.00 0<br />

II Krapinsko-zagorska 0 0 0 0 2.00 0<br />

III Sisačko-moslavačka 0 0 0 0 0 0<br />

IV Karlovačka 40.00 0.52 0 0 8.00 1.67<br />

V Varaždinska 0 0 0 0 2.00 29.37<br />

VI Koprivničko-križevačka 140.00 0 0 0 5.00 1.88<br />

VII Bjelovarsko-bilogorska 0 0 0 0 1.50 13.07<br />

VIII Primorsko-goranska 0 6.77 6.00 0.047 30.50 0<br />

IX Ličko-senjska 383.00 0.19 23.00 0.047 7.50 0<br />

X Virovitičko-podravska 0 0 0 0 0 0<br />

XI Požeško-slavonska 0 1.39 0 0 2.00 0<br />

XII Brodsko-posavska 0 0 0 0 4.00 0<br />

XIII Zadarska 0 6.58 34.95 0.056 0 0<br />

XIV Osječko-baranjska 0 0 0 0 32.00 0<br />

XV Šibensko-kninska 0 7.86 23.10 0.056 0 0<br />

XVI Vukovarsko-srijemska 0 0 0 0 3.00 1.88<br />

XVII Splitsko-dalmatinska 0 2.96 217.15 0.113 4.00 0<br />

XVIII Istarska 0 0 0 0.047 3.00 0<br />

XIX Dubrovačko-neretvanska 63.00 2.21 74.00 0.056 1.00 0<br />

XX Međimurska 0 0 0 0.007 0 0<br />

XXI City of Zagreb 44.00 0 0 0.007 0 0<br />

Total 709.00 29.26 378.20 0.444 111.50 47.87<br />

On the contrary, thermal solar systems for production of<br />

hot water will be used extensively due to their good<br />

economy. For the time being the main obstacle to wider<br />

usage of solar domestic water heating systems is non-<br />

3