PLC<br />

9<br />

In this operating mode, the PLC may be accessed to check its operation or the status of its variables.<br />

It is also possible to edit or analyze the PLC program as well as the message or the error files of<br />

the PLC.<br />

The accessible programs associated with the PLC are:<br />

The PLC program (PLC_PRG)<br />

The PLC error file (PLC_ERR)<br />

The PLC message file (PLC_MSG)<br />

The PLC program (PLC_PRG) may be edited at the front panel or copied from the hard disk (KeyCF)<br />

or from a PC as described in the "Utilities" chapter.<br />

The PLC program (PLC_PRG) is stored in the internal CNC memory with the part-programs and<br />

it is displayed in the program directory (utilities) together with the part-programs.<br />

Before executing the PLC_PRG program, it must be compiled. Once it is done compiling, the CNC<br />

requests whether the PLC should be started or not. To make the operator life easier and avoid new<br />

compilations, the source code generated at each compilation is stored in memory.<br />

After power-up, the CNC acts as follows:<br />

Is there an<br />

executable code?<br />

No<br />

Is there a<br />

No<br />

Is there a<br />

PLC_PRG in<br />

No<br />

Yes<br />

Yes<br />

Yes<br />

The PLC compiles and<br />

generates the executable<br />

RUN END<br />

Runs the executable program stored in memory.<br />

If there isn't one, it compiles the PLC_PRG<br />

program already in memory and runs the resulting<br />

executable program.<br />

If it is not there, it looks for it in the hard disk<br />

(KeyCF).<br />

If it isn't in the hard disk (KeyCF) either, it does<br />

nothing. Later on, when accessing the jog mode,<br />

execution mode, etc. the CNC will issue the<br />

corresponding error message.<br />

Once the program has been compiled, it is not necessary to keep the source program (PLC_PRG)<br />

in memory because the PLC always executes the executable program.<br />

Once the proper performance of the PLC has been verified, it is a good idea to save it into the hard<br />

disk (KeyCF) using the instruction SAVE PROGRAM (as described later on).<br />