Create window<br />
This CNC allows the possibility of creating windows to display the status of the various PLC<br />
resources. These windows will be shown overlapping the PLC program and the information<br />
displayed in them will be updated dynamically.<br />
The options "MODIFY WINDOW", "ACTIVE WINDOW" and "ACTIVATE SYMBOLS" allow the<br />
manipulation of these windows.<br />
Every time a new window is created, the CNC will assign 2 data lines to it in order to display the<br />
status of the desired resources.<br />
There are two types of windows which can be selected with softkeys.<br />
Window to display timers and registers<br />
This window is divided into two sections, one to display timers and the other one to display registers.<br />
Timer.<br />
It will show one timer per line showing the following information for each one of them:<br />
TG Indicates the logic status of the active trigger input.<br />
M Indicates the status of the timer: "S" means stopped, "T" means timing and "D"<br />
means disabled.<br />
TEN Indicates the logic status of the enable input.<br />
TRS Indicates the logic status of the enable input.<br />
T Indicates the logic status of the status output of the timer.<br />
ET Indicates the elapsed time.<br />
TO Indicates the remaining time.<br />
Key in the command T 1/256 or T 1/256.1/256 to request the data on a timer or group of timers and<br />
then press [ENTER].<br />
Register.<br />
It will display one register per line showing the following information fields for each of them:<br />
HEX Indicates the hexadecimal value of its contents.<br />
DEC Indicates the decimal value of its contents (with sign).<br />
Key in R 1/559 or R 1/559.1/559 to request information on one or more registers and, then, press<br />
[ENTER].<br />
Window to display counters and binary data<br />
This window is divided into two sections, one to display counters and the other one to display binary<br />
data.<br />
Counters.<br />
It will display one counter per line showing the following information fields for each of them:<br />
CEN Indicates the logic status of the enable input.<br />
CUP Indicates the logic status of the UP COUNT input.<br />
CDW Indicates the logic status of the DOWN COUNT input.<br />
CPR Indicates the logic status of the preset input.<br />
S Indicates the status of the counter. "1" when its internal count is 0 and 0 for all<br />
other cases.<br />
C Indicates its count value.<br />
Key in C 1/256 or C 1/256.1/256 to request information on one or more counter and, then, press<br />
[ENTER].<br />