Operating manual<br />
12.<br />
DIAGNOSIS<br />
Adjustments<br />
CNC 8035<br />
·T· MODEL<br />
(SOFT V16.3X)<br />
·222·<br />
The trigger condition starts evaluating after having the indicated % of samples. If the position<br />
is defined as 50% and the trigger condition takes place after taking 10% of the samples, it is<br />
ignored until capturing 50% of the samples.<br />
Number of samples<br />
It indicates the number of sample to be captured. It is common to all the channels. Value between<br />
1 and 1024.<br />
The sample will be taken at the same time in all the channels so they are synchronized.<br />
Sample T<br />
It indicates the sampe period or the time period between data captures. It is given in milliseconds,<br />
integers between 1 and 1000 (between 1ms and 1s).<br />
When analyzing CNC variables, the sample period must be a multiple of the loop time. If it is<br />
not, a message is displayed indicating that the sampling period has been automatically rounded<br />
off.<br />
The sample time may be shorter than the CNC loop time only when analyzing 1 or 2 variables<br />
of the same drive.<br />
Mode<br />
It indicates the type of data capture, single or continuous.<br />
With "single" capture, the process ends when the specified number of samples has been taken<br />
or when interrupted by the user.<br />
In continuous capture mode, when the trace fills up the screen, the capture goes on except if<br />
the trigger has triggered; in that case the trace of the trigger remains until a new trigger is<br />
activated. The process goes on like that indefinitely until the user stops it.<br />
Superimposed channels<br />
If this option is not selected, all the signals appear separated. The screen is divided into as many<br />
horizontal strips as active and visible channels have been defined. The signals are shown with<br />
their own graphic zero and ordered from top to bottom in the defined order (CH1, CH2, CH3,<br />
CH4).<br />
If this option is selected all the signals appear superimposed, with a single graphic zero located<br />
at the center of the screen.<br />
During the analysis of the signals, it is possible to change modes by pressing the [M] key.<br />
Machine parameter setting<br />
The parameters defining page shows the definition code on the left column, the parameter name<br />
on the center column and the maximum and minimum values on the right column.<br />
To add a parameter to the list, select the row for the parameter, enter the definition code and<br />
press [ENTER]. If the parameter is valid, the rest of the fields are updated and if not, it issues<br />
a warning.<br />
To replace a parameter from the list, select the parameter to be replaced, enter the definition<br />
code of the new parameter and press [ENTER]. If the previous content has been deleted and<br />
no code is entered, the line appears empty.<br />
The [Add a parameter to the list] softkey enters a new empty line above the currently selected line.<br />
The [Eliminate parameter] softkey eliminates the currently selected line and shifts all the ones<br />
below upwards.<br />
The parameters are always shown in the same place where they were defined and the empty rows<br />
appear blank.<br />
When a parameter is changed, the CNC machine parameter table and the drive's work parameters<br />
are updated. The [Save parameters] softkey is also activated. It is recommended to save the<br />
parameter tables that have been changed, those of the CNC into the "KeyCF" and those of the drive<br />
in its FLASH. If only the CNC parameters have been changed, the drive tables remain unchanged<br />
and vice versa.<br />
Once the values saved are the same as the ones edited last, the softkey disappears until a new<br />
modification is made.<br />
CNC machine parameters that may be modified<br />
General machine parameters: Enter the indicator of the general parameter and the parameter<br />
number separated with a dot.