Operating manual<br />
11.<br />
MACHINE PARAMETERS<br />
Operation with parameter tables<br />
CNC 8035<br />
·T· MODEL<br />
(SOFT V16.3X)<br />
·210·<br />
11.5 Operation with parameter tables<br />
Once the desired table has been selected, the CNC will show its contents and the cursor can be<br />
moved line by line with the [] [] keys or page by page with the "page up" and "page down" keys.<br />
There are also several options to operate with those tables. These options are shown with softkeys<br />
and they are:<br />
Once any of those options has been selected, the user can move the cursor over this line by means<br />
of the [] [] keys. Also, with the [] key, the cursor may be placed over the first character of the<br />
editing window and, with the [] key over the last character.<br />
"EDIT" softkey<br />
With this option it is possible to edit the selected parameter. Once this option has been selected,<br />
the softkeys will change colors and they will appear over white background showing the information<br />
corresponding to the type of editing possible at that point.<br />
In those tables corresponding to leadscrew and cross compensation, the position values of the axis<br />
must be edited as follows:<br />
1. Move the axis and when the error is found large enough to be considered, press the softkey<br />
corresponding to this axis.<br />
2. The CNC will include, in the editing area, the name of the axis followed by the position value<br />
corresponding to that point. This value can be modified if so desired.<br />
<strong>3.</strong> Press the softkey corresponding to the error and key in its value.<br />
Once the parameter is edited, press [ENTER]. This new parameter will be included in the table and<br />
the cursor will be positioned over it. The editing area will be cleared, thus allowing other parameters<br />
to be edited.<br />
Press [ESC] to quit this mode.<br />
"MODIFY" softkey<br />
With this option it is possible to modify the selected parameter. Before pressing this softkey, the<br />
desired parameter must be selected.<br />
When selecting this option, the softkeys will change their color to a white background and they will<br />
show the various editing options.<br />
By pressing [ESC], the information displayed in the editing window (corresponding to the selected<br />
parameter) will be cleared. From this point on, a new value can be entered.<br />
To quit the block modifying mode, press [CL] or [ESC] to clear the editing window and then press<br />
[ESC] again. The selected parameter will not be modified.<br />
Once this modification has concluded, press the [ENTER] key to validate it. The new parameter will<br />
replace the previous one.