Operating manual<br />

9.<br />

PLC<br />

Monitoring<br />

CNC 8035<br />

·T· MODEL<br />

(SOFT V16.3X)<br />

·164·<br />

Binary Data.<br />

It will show one data line per resource or group of resources requested.<br />

The instructions available to request information of the various resources are:<br />

I 1/256 or I 1/256.1/256 Shows the status of the selected input or group of inputs.<br />

O 1/256 or O 1/256.1/256 Shows the status of the selected output or group of outputs.<br />

M 1/5957 or M 1/5957.1/5957Shows the status of the selected mark or group of marks.<br />

B 0/31 R 1/559 Shows the status of the selected bit of the indicated register.<br />

When requesting the status of one or more inputs, outputs or marks, the CNC will show complete<br />

data lines even when all of them have not been requested.<br />

When using generic denominators (I / O / M) to display resources, the CNC will display 20 of them<br />

per line and 3 when using their associated mnemonics (symbols).<br />

When requesting the status of a register bit, the CNC will display only the requested bit on the<br />

corresponding line.<br />

Modify window.<br />

With this option it is possible to manipulate the active window (the one selected) by enlarging it,<br />

reducing it, clearing it or even eliminating (closing) it.<br />

To do so, the following softkey options are available:<br />

ENLARGE To enlarge the size of the window by one line every time this softkey is pressed.<br />

REDUCE To reduce the size of the window by one line every time this softkey is pressed<br />

(minimum 2 lines).<br />

CLEAR To clear the contents of the active window.<br />

CLOSE To close the active window. When closing a window, the CNC will no longer<br />

display it.<br />

Active window.<br />

With this option it is possible to select between the PLC program and each one of the windows being<br />

displayed (timers, registers, counters and binary data) in order to operate with it.<br />

Bear in mind that the operator can only operate with the active window.<br />

Once the active window has been selected, it will be possible to:<br />

Move the cursor (if the PLC program is the one active) or shift the display area with the [] []<br />

keys.<br />

Execute any command of the "MODIFY WINDOW" option.