Operating manual<br />

9.<br />

PLC<br />

Monitoring<br />

CNC 8035<br />

·T· MODEL<br />

(SOFT V16.3X)<br />

·170·<br />

"Autozoom" softkey<br />

The "Autozoom" softkey only appears when a block that is being monitored is too long and does<br />

not fit on the screen.<br />

Pressing this softkey automatically adjusts the displayed blocks to the width of the screen. This way,<br />

the CNC shows the whole block without having to scroll it with the keys.<br />

After having pressed the "Autozoom" softkey, if the blocks are too small, the CNC will not show the<br />

data of the elements. Also, if autozoom has been activated, it is not possible to scroll up and down<br />

toward blocks that are not displayed on the screen.<br />

"Finish" softkey<br />

It may be used to exit the PLC monitoring screen in ladder diagram.<br />

Elements of the PLC program<br />

As mentioned earlier, the instructions of the PLC program in ladder language is made up of elements<br />

connected to each other by segments. These elements may be the following:<br />

i<br />

Normally open contact:<br />

The normally open contact is always displayed in the consultations area. Consults the logic state<br />

of a signal and, depending on the result, lets the flow pass or not.<br />

Normally closed contact:<br />

The normally closed contact is always displayed in the consultations area. Consults the logic<br />

state of a signal and, depending on the result, lets the flow pass or not.<br />

Relay coil:<br />

All the elements may appear in the PLC program in ladder language joined together<br />

in serial or in parallel.<br />

Comments are not displayed when monitoring the PLC program in ladder language.<br />

I10<br />

If I10 = 0, the contact is inactive and the flow does not pass.<br />

If I10 = 1, the contact is active and the flow passes.<br />

M100<br />

If M100 = 0, the contact is active and the flow passes.<br />

If M100 = 1, the contact is inactive and the flow does not pass.<br />

The relay coil is always displayed in the actions area. It activates or deactivates depending on<br />

whether it receives the flow or not.<br />

O1<br />

If the flow reaches the relay coil, it will be active and its value will be O1 = 1.<br />

If the flow does not reach the relay coil, it will be inactive and its value will be O1 = 0.