12.6 Interesting notes<br />

The CNC carries out a series of sequential tests. If the result obtained is not correct, it may stop<br />

axes feed and spindle rotation (by canceling their analog voltages and Enables), as well as stopping<br />

the execution of the PLC program or activating the external emergency output (01).<br />

Type of test When doing Stop axes and<br />

spindles<br />

Stop the PLC Activates the<br />

emergency<br />

output<br />

Temperature Always Yes No Yes<br />

Battery out Always No No No<br />

Flash memory From Diagnosis Yes Yes Yes<br />

(KeyCF) On power-up No No No<br />

RAM memory From Diagnosis Yes No Yes<br />

External power supply. EXEC/SIMUL Yes No No<br />

Board voltage EXEC/SIMUL Yes No Yes<br />

PLC in execution EXEC/SIMUL Yes --- Yes<br />

PLC User errors EXEC/SIMUL Yes No No<br />

PLC watchdog PLC in execution Yes Yes Yes<br />

Operating manual<br />

DIAGNOSIS<br />

Interesting notes 12.<br />

CNC 8035<br />

·T· MODEL<br />

(SOFT V16.3X)<br />

·229·