"CLEAR ALL" softkey<br />

This option deletes all the variables from the status window.<br />

Selection of trigger condition<br />

The trigger condition is defined as the condition used to capture the data. Also, the capture may<br />

be done before, after or before and after meeting the selected trigger condition.<br />

This option may be used to select the trigger type and condition of the logic analyzer. To do this,<br />

the softkeys will show the following options:<br />

"EDIT" softkey<br />

It may be used to edit or modify the trigger condition to capture the data to be analyzed.<br />

Once this option has been selected, the softkeys will change colors and they will appear over white<br />

background showing the information corresponding to the type of editing possible at that point.<br />

It is possible to define any logic expression and it may consist of one or several consultations that<br />

must follow the syntax and rules used in PLC equations.<br />

Example of expressions and trigger instant:<br />

M100 The trigger occurs when M100 = 1.<br />

NOT M100 The trigger occurs when M100 = 0.<br />

CPS R100 EQ 1 The trigger occurs when R100 = 1.<br />

NOT I20 AND I5 The trigger occurs when this expression is true.<br />

No more than 16 flank detecting instructions (DFU and DFD) can be used between all the definitions<br />

of variables and the selected trigger condition.<br />

Pressing the [ESC] key deletes the trigger condition being edited. From this point on, the condition<br />

may be edited again.<br />

Once the trigger has been edited, press [ENTER]. The new edited condition will be shown in the<br />

information window.<br />

If no trigger condition has been specified, the system considers that it is a default trigger and it will<br />

show the message "Trigger type": DEFAULT" in the information window. On the other hand, it is not<br />

be possible to select any of the possible trigger conditions (trigger before, trigger center, trigger<br />

after).<br />

"TRIGGER BEFORE" softkey<br />

The CNC starts capturing data from the moment when the selected trigger condition is met.<br />

Then, once the trace has been executed, the trigger (vertical red line) will be shown at the beginning<br />

of the trace.<br />

"TRIGGER AFTER" softkey<br />

The CNC starts capturing data from the moment when the option to execute the trace is selected.<br />

The trace will be completed when the selected trigger condition is met.<br />

The system will show the trigger (vertical red line) at the end of the trace.<br />

"TRIGGER CENTER" softkey<br />

The CNC starts capturing data from the moment when the option to execute the trace is selected.<br />

Then, once the trace has been executed, the trigger (vertical red line) will be shown in the middle<br />

of the trace.<br />

Operating manual<br />

PLC<br />

Logic analyzer 9.<br />

CNC 8035<br />

·T· MODEL<br />

(SOFT V16.3X)<br />