66 State of the Art<br />
figure 35: AFMP measure on a TC-OTFT pentacene based device [42]; close to the contacts it is<br />
evident the effect of the Schottky barrier and the damage caused by the deposition of the metal<br />
contacts.<br />
As already mentioned, it 'also important to note the reasons<br />
that cause a drastically different behaviors for the metal contacts<br />
depending on whether they are used in BC or TC topologies.<br />
From the physical point of view, an analysis similar to the one<br />
already seen, the KFM (Kelvin Probe Force Microscopy), is also<br />
useful in this direction as shown by Puntambekar, Pesavento and<br />
Frisbie [44] in a comparison of potential profiles expressed by<br />
structures bottom-contacts and top-contacts-contacts respectively<br />
(figure 36).