Sampling Guide for Air Contaminants in the Workplace - Irsst
Sampling Guide for Air Contaminants in the Workplace - Irsst
Sampling Guide for Air Contaminants in the Workplace - Irsst
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
ROHS Substances table<br />
90<br />
ROHS Name<br />
CAS<br />
TWAEV<br />
STEV<br />
Ceil<strong>in</strong>g<br />
(mg/m³)<br />
Notes<br />
<strong>Sampl<strong>in</strong>g</strong><br />
Device<br />
Flow<br />
L/m<strong>in</strong><br />
Volume<br />
TWAEV<br />
STEV<br />
(L)<br />
Pr<strong>in</strong>ciple<br />
MRV<br />
µg<br />
CVa<br />
(%)<br />
#<br />
meth.<br />
Remarks<br />
Isophorone diisocyanate<br />
4098-71-9<br />
0,045 EM<br />
S<br />
Millipore AP4003705 glass fiber filter<br />
pretreated <strong>in</strong> <strong>the</strong> laboratory <strong>in</strong> series with<br />
a Teflon filter #MSI Z50WP03700<br />
917 PTF filter<br />
GF filter<br />
Vial<br />
1 HPLC-UV- 0,038<br />
Flu<br />
15 IRSST<br />
376<br />
Refer to <strong>the</strong> sampl<strong>in</strong>g guidel<strong>in</strong>es supplied with <strong>the</strong> equipment. If more than one<br />
isocyanate is requested, provide a process sample.<br />
The two filters <strong>in</strong> <strong>the</strong> sampl<strong>in</strong>g cassette allow specific analysis of monomer HDI <strong>in</strong><br />
vapour <strong>for</strong>m and <strong>in</strong> aerosol <strong>for</strong>m. The result supplied <strong>in</strong> <strong>the</strong> report is <strong>the</strong> sum of<br />
<strong>the</strong> monomers of IPDI of <strong>the</strong> two fractions. Determ<strong>in</strong>ation of <strong>the</strong> correspond<strong>in</strong>g<br />
oligomers is also done dur<strong>in</strong>g <strong>the</strong> analysis. HDI can be determ<strong>in</strong>ed<br />
simultaneously on <strong>the</strong> same sample. Note that <strong>the</strong> analytical method does not<br />
differentiate IPDI oligomers from HDI oligomers. The sampl<strong>in</strong>g time can be<br />
longer than 15 m<strong>in</strong>utes if <strong>the</strong> IPDI is present <strong>in</strong> vapour <strong>for</strong>m only.<br />
Isopropoxyethanol<br />
109-59-1<br />
106 Pc Activated charcoal tube 100/50mg<br />
0,1 10 GC-FID<br />
OSHA<br />
07<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
OSHA method 07 is <strong>for</strong> organic vapours and can be adapted to<br />
isopropoxyethanol.<br />
Isopropyl acetate<br />
108-21-4<br />
1040<br />
1290<br />
SKC 226-01 activated charcoal tube<br />
2120 Activated charcoal 100/50 mg<br />
Max:<br />
0,2<br />
10<br />
3<br />
GC-FID<br />
475<br />
IRSST<br />
279-1<br />
The analysis can be done by gas chromatography coupled with mass<br />
spectrometry (GC-MS, IRSST method #369); <strong>in</strong> this case <strong>the</strong> analytical<br />
uncerta<strong>in</strong>ty (CVa) is 0.74%.<br />
Isopropyl alcohol<br />
67-63-0<br />
983<br />
1230<br />
3M 3500 organic vapour monitor<br />
2695 Passive dosimeter<br />
0,0394 GC-FID 100 5,0<br />
IRSST<br />
93-1<br />
For <strong>the</strong> monitors, <strong>the</strong> flow must be considered as be<strong>in</strong>g a sampl<strong>in</strong>g rate.<br />
Accord<strong>in</strong>g to <strong>the</strong> data from 3M, <strong>the</strong> precision (CVsampl<strong>in</strong>g) of <strong>the</strong> sampl<strong>in</strong>g rate is<br />
5%. Refer to <strong>the</strong> 3M passive monitor guide on <strong>the</strong> IRSST's Web site.<br />
Isopropyl alcohol<br />
67-63-0<br />
983<br />
1230<br />
SKC 226-01 activated charcoal tube<br />
2120 Activated charcoal 100/50 mg<br />
Max:<br />
0,2<br />
3<br />
3<br />
GC-FID<br />
100 5,0<br />
IRSST<br />
93-1<br />
The analysis can be done by gas chromatography coupled with mass<br />
spectrometry (GC-MS, IRSST method #369); <strong>in</strong> this case <strong>the</strong> analytical<br />
uncerta<strong>in</strong>ty (CVa) is 4.8%.<br />
Isopropyl glycidyl e<strong>the</strong>r<br />
(IGE)<br />
238<br />
356<br />
Activated charcoal tube 100/50 mg<br />
0,01-<br />
0,2<br />
30<br />
3<br />
GC-FID<br />
NIOSH<br />
1620<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
4016-14-2<br />
Isopropylam<strong>in</strong>e<br />
75-31-0<br />
12<br />
24<br />
Impregnated glass fiber filter, Millipore<br />
AP4003705<br />
955 Impregned FGF<br />
1 HPLC-MS 9<br />
15 IRSST<br />
363<br />
Anil<strong>in</strong>e, diethanolam<strong>in</strong>e, dimethylam<strong>in</strong>e, ethanolam<strong>in</strong>e, isopropylam<strong>in</strong>e,<br />
methylam<strong>in</strong>e and morphol<strong>in</strong>e can be sampled at <strong>the</strong> same time.<br />
N-Isopropylanil<strong>in</strong>e<br />
768-52-5<br />
11 Pc Two glass fiber filters impregnated with 1 100 HPLC-UV<br />
OSHA<br />
78<br />
sulfuric acid.<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.