ROHS Substances table<br />

90<br />

ROHS Name<br />

CAS<br />

TWAEV<br />

STEV<br />

Ceil<strong>in</strong>g<br />

(mg/m³)<br />

Notes<br />

<strong>Sampl<strong>in</strong>g</strong><br />

Device<br />

Flow<br />

L/m<strong>in</strong><br />

Volume<br />

TWAEV<br />

STEV<br />

(L)<br />

Pr<strong>in</strong>ciple<br />

MRV<br />

µg<br />

CVa<br />

(%)<br />

#<br />

meth.<br />

Remarks<br />

Isophorone diisocyanate<br />

4098-71-9<br />

0,045 EM<br />

S<br />

Millipore AP4003705 glass fiber filter<br />

pretreated <strong>in</strong> <strong>the</strong> laboratory <strong>in</strong> series with<br />

a Teflon filter #MSI Z50WP03700<br />

917 PTF filter<br />

GF filter<br />

Vial<br />

1 HPLC-UV- 0,038<br />

Flu<br />

15 IRSST<br />

376<br />

Refer to <strong>the</strong> sampl<strong>in</strong>g guidel<strong>in</strong>es supplied with <strong>the</strong> equipment. If more than one<br />

isocyanate is requested, provide a process sample.<br />

The two filters <strong>in</strong> <strong>the</strong> sampl<strong>in</strong>g cassette allow specific analysis of monomer HDI <strong>in</strong><br />

vapour <strong>for</strong>m and <strong>in</strong> aerosol <strong>for</strong>m. The result supplied <strong>in</strong> <strong>the</strong> report is <strong>the</strong> sum of<br />

<strong>the</strong> monomers of IPDI of <strong>the</strong> two fractions. Determ<strong>in</strong>ation of <strong>the</strong> correspond<strong>in</strong>g<br />

oligomers is also done dur<strong>in</strong>g <strong>the</strong> analysis. HDI can be determ<strong>in</strong>ed<br />

simultaneously on <strong>the</strong> same sample. Note that <strong>the</strong> analytical method does not<br />

differentiate IPDI oligomers from HDI oligomers. The sampl<strong>in</strong>g time can be<br />

longer than 15 m<strong>in</strong>utes if <strong>the</strong> IPDI is present <strong>in</strong> vapour <strong>for</strong>m only.<br />

Isopropoxyethanol<br />

109-59-1<br />

106 Pc Activated charcoal tube 100/50mg<br />

0,1 10 GC-FID<br />

OSHA<br />

07<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

OSHA method 07 is <strong>for</strong> organic vapours and can be adapted to<br />

isopropoxyethanol.<br />

Isopropyl acetate<br />

108-21-4<br />

1040<br />

1290<br />

SKC 226-01 activated charcoal tube<br />

2120 Activated charcoal 100/50 mg<br />

Max:<br />

0,2<br />

10<br />

3<br />

GC-FID<br />

475<br />

IRSST<br />

279-1<br />

The analysis can be done by gas chromatography coupled with mass<br />

spectrometry (GC-MS, IRSST method #369); <strong>in</strong> this case <strong>the</strong> analytical<br />

uncerta<strong>in</strong>ty (CVa) is 0.74%.<br />

Isopropyl alcohol<br />

67-63-0<br />

983<br />

1230<br />

3M 3500 organic vapour monitor<br />

2695 Passive dosimeter<br />

0,0394 GC-FID 100 5,0<br />

IRSST<br />

93-1<br />

For <strong>the</strong> monitors, <strong>the</strong> flow must be considered as be<strong>in</strong>g a sampl<strong>in</strong>g rate.<br />

Accord<strong>in</strong>g to <strong>the</strong> data from 3M, <strong>the</strong> precision (CVsampl<strong>in</strong>g) of <strong>the</strong> sampl<strong>in</strong>g rate is<br />

5%. Refer to <strong>the</strong> 3M passive monitor guide on <strong>the</strong> IRSST's Web site.<br />

Isopropyl alcohol<br />

67-63-0<br />

983<br />

1230<br />

SKC 226-01 activated charcoal tube<br />

2120 Activated charcoal 100/50 mg<br />

Max:<br />

0,2<br />

3<br />

3<br />

GC-FID<br />

100 5,0<br />

IRSST<br />

93-1<br />

The analysis can be done by gas chromatography coupled with mass<br />

spectrometry (GC-MS, IRSST method #369); <strong>in</strong> this case <strong>the</strong> analytical<br />

uncerta<strong>in</strong>ty (CVa) is 4.8%.<br />

Isopropyl glycidyl e<strong>the</strong>r<br />

(IGE)<br />

238<br />

356<br />

Activated charcoal tube 100/50 mg<br />

0,01-<br />

0,2<br />

30<br />

3<br />

GC-FID<br />

NIOSH<br />

1620<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

4016-14-2<br />

Isopropylam<strong>in</strong>e<br />

75-31-0<br />

12<br />

24<br />

Impregnated glass fiber filter, Millipore<br />

AP4003705<br />

955 Impregned FGF<br />

1 HPLC-MS 9<br />

15 IRSST<br />

363<br />

Anil<strong>in</strong>e, diethanolam<strong>in</strong>e, dimethylam<strong>in</strong>e, ethanolam<strong>in</strong>e, isopropylam<strong>in</strong>e,<br />

methylam<strong>in</strong>e and morphol<strong>in</strong>e can be sampled at <strong>the</strong> same time.<br />

N-Isopropylanil<strong>in</strong>e<br />

768-52-5<br />

11 Pc Two glass fiber filters impregnated with 1 100 HPLC-UV<br />

OSHA<br />

78<br />

sulfuric acid.<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.