Sampling Guide for Air Contaminants in the Workplace - Irsst
Sampling Guide for Air Contaminants in the Workplace - Irsst
Sampling Guide for Air Contaminants in the Workplace - Irsst
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
ROHS Substances table<br />
109<br />
ROHS Name<br />
CAS<br />
TWAEV<br />
STEV<br />
Ceil<strong>in</strong>g<br />
(mg/m³)<br />
Notes<br />
<strong>Sampl<strong>in</strong>g</strong><br />
Device<br />
Flow<br />
L/m<strong>in</strong><br />
Volume<br />
TWAEV<br />
STEV<br />
(L)<br />
Pr<strong>in</strong>ciple<br />
MRV<br />
µg<br />
CVa<br />
(%)<br />
#<br />
meth.<br />
Remarks<br />
meta-Phenylenediam<strong>in</strong>e<br />
108-45-2<br />
0,1 Two glass fiber filters treated with 0.26N 1 100 HPLC-UV<br />
OSHA<br />
87<br />
sulfuric acid<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Sample is stable <strong>for</strong> 15 days at ambient temperature.<br />
ortho-Phenylenediam<strong>in</strong>e<br />
95-54-5<br />
0,1 C2<br />
EM<br />
Two glass fiber filters treated with 0.26N<br />
sulfuric acid<br />
1 100 HPLC-UV<br />
OSHA<br />
87<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Sample is stable <strong>for</strong> 15 days at ambient temperature.<br />
p-Phenylenediam<strong>in</strong>e<br />
106-50-3<br />
0,1 Pc<br />
S<br />
Two SKC FLT225-7 glass fiber filters<br />
impregnated with sulfuric acid.<br />
1 100 HPLC-UV<br />
OSHA<br />
87<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Phenylhydraz<strong>in</strong>e<br />
100-63-0<br />
0,44 Pc<br />
C2<br />
RP<br />
EM<br />
Glass fritted tip imp<strong>in</strong>ger conta<strong>in</strong><strong>in</strong>g 15 mL<br />
of 0.1N HCL<br />
0,2-1 100 UV/VIS-S<br />
NIOSH<br />
3518<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
n-Phenyl-ßnaphthylam<strong>in</strong>e<br />
135-88-6<br />
C2<br />
RP<br />
EM<br />
Two pretreated glass fiber filters<br />
1 240 HPLC-UV<br />
OSHA<br />
96<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Phenylphosph<strong>in</strong>e<br />
638-21-1<br />
--<br />
--<br />
0,23<br />
RP<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
No support<strong>in</strong>g reference is suggested <strong>for</strong> this product.<br />
Phorate<br />
298-02-2<br />
0,05<br />
0,2<br />
Pc OVS-2 tube with XAD-2 and glass fiber 0,2-1 240 GC-FPD<br />
filter<br />
15<br />
NIOSH<br />
5600<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Some phosphates may cause <strong>in</strong>terference dur<strong>in</strong>g <strong>the</strong> analysis.<br />
Phosdr<strong>in</strong><br />
7786-34-7<br />
0,092<br />
0,27<br />
Pc OVS-2 tube with XAD-2 and glass fiber 0,2-1 240 GC-FPD<br />
filter<br />
15<br />
NIOSH<br />
5600<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Some phosphates may cause <strong>in</strong>terference dur<strong>in</strong>g <strong>the</strong> analysis.<br />
Phosgene<br />
75-44-5<br />
0,4 XAD-2 tube impregnated with 2-<br />
1 240 GC-NPD<br />
OSHA<br />
61<br />
(hydroxymethyl) piperid<strong>in</strong>e<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Phosph<strong>in</strong>e<br />
7803-51-2<br />
0,42<br />
1,4<br />
Pretreated glass fiber filter <strong>in</strong> series with a<br />
polyester filter pretreated with mercuric<br />
chloride<br />
1 240 ICP<br />
OSHA<br />
1003<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g. Stable <strong>for</strong> at least 17 days at ambient<br />
temperature.