07.03.2014 Views

Sampling Guide for Air Contaminants in the Workplace - Irsst

Sampling Guide for Air Contaminants in the Workplace - Irsst

Sampling Guide for Air Contaminants in the Workplace - Irsst

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ROHS Substances table<br />

65<br />

ROHS Name<br />

CAS<br />

TWAEV<br />

STEV<br />

Ceil<strong>in</strong>g<br />

(mg/m³)<br />

Notes<br />

<strong>Sampl<strong>in</strong>g</strong><br />

Device<br />

Flow<br />

L/m<strong>in</strong><br />

Volume<br />

TWAEV<br />

STEV<br />

(L)<br />

Pr<strong>in</strong>ciple<br />

MRV<br />

µg<br />

CVa<br />

(%)<br />

#<br />

meth.<br />

Remarks<br />

Cyanides (as Cn)<br />

57-12-5<br />

--<br />

--<br />

11<br />

Pc<br />

RP<br />

Glass midget imp<strong>in</strong>ger conta<strong>in</strong><strong>in</strong>g 15 mL<br />

of 0,1 N potassium hydroxide<br />

0,5-1,0 SE<br />

180 NIOSH<br />

7904<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g. For surface wipe sampl<strong>in</strong>g, use surface kit<br />

#3020.<br />

Some anions and metals can cause <strong>in</strong>terference.<br />

Cyanogen<br />

460-19-5<br />

21 XAD-2 tube impregnated with 2-<br />

0,2 12 GC-NPD<br />

OSHA<br />

PV2104<br />

(hydroxymethyl) piperid<strong>in</strong>e<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Cyanogen chloride<br />

506-77-4<br />

--<br />

--<br />

0,75<br />

RP XAD-2 tube impregnated with 2-<br />

0,2 1 GC-NPD<br />

OSHA<br />

IMISC146<br />

hydroxymethyl piperid<strong>in</strong>e<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Cyclohexane<br />

110-82-7<br />

1030 SKC 226-01 activated charcoal tube<br />

Max: 3 GC-FID 160<br />

IRSST<br />

194-1<br />

2120 Activated charcoal 100/50 mg<br />

0,2<br />

The analysis can be done by gas chromatography coupled with mass<br />

spectrometry (GC-MS, IRSST method #369); <strong>in</strong> this case <strong>the</strong> analytical<br />

uncerta<strong>in</strong>ty (CVa) is 0.56%.<br />

Cyclohexane<br />

110-82-7<br />

1030 0,0324 GC-FID 160<br />

IRSST<br />

194-1<br />

3M 3500 organic vapour monitor<br />

2695 Passive dosimeter<br />

For <strong>the</strong> monitors, <strong>the</strong> flow must be considered as be<strong>in</strong>g a sampl<strong>in</strong>g rate.<br />

Accord<strong>in</strong>g to <strong>the</strong> data from 3M, <strong>the</strong> precision (CVsampl<strong>in</strong>g) of <strong>the</strong> sampl<strong>in</strong>g rate is<br />

2.2%. Refer to <strong>the</strong> 3M passive monitor guide on <strong>the</strong> IRSST's Web site.<br />

Cyclohexanol<br />

108-93-0<br />

206 Pc SKC 226-01 activated charcoal tube<br />

Max: 10 GC-FID 100<br />

IRSST<br />

134-1<br />

2120 Activated charcoal 100/50 mg<br />

0,2<br />

Cyclohexanone<br />

108-94-1<br />

100 Pc SKC ST226-110 Chromosorb-106 tube Max: 10 GC-FID 20 2,0 IRSST<br />

135-1<br />

2127 Chromosorb-106<br />

0,2<br />

Cyclohexanone must be sampled specifically due to <strong>the</strong> sampl<strong>in</strong>g device used.<br />

Cyclohexene<br />

110-83-8<br />

1010 Activated charcoal tube 100/50 mg<br />

0,2 7 GC-FID<br />

NIOSH<br />

1500<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Cyclohexylam<strong>in</strong>e<br />

108-91-8<br />

41 Silica gel tube 150/75mg<br />

0,01-1 3 GC-FID<br />

NIOSH<br />

2010<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Cyclonite<br />

121-82-4<br />

1,5 Pc Glass fiber filter<br />

1 120 HPLC-UV<br />

OSHA<br />

PV2135<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!