Sampling Guide for Air Contaminants in the Workplace - Irsst
Sampling Guide for Air Contaminants in the Workplace - Irsst
Sampling Guide for Air Contaminants in the Workplace - Irsst
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
ROHS Substances table<br />
68<br />
ROHS Name<br />
CAS<br />
TWAEV<br />
STEV<br />
Ceil<strong>in</strong>g<br />
(mg/m³)<br />
Notes<br />
<strong>Sampl<strong>in</strong>g</strong><br />
Device<br />
Flow<br />
L/m<strong>in</strong><br />
Volume<br />
TWAEV<br />
STEV<br />
(L)<br />
Pr<strong>in</strong>ciple<br />
MRV<br />
µg<br />
CVa<br />
(%)<br />
#<br />
meth.<br />
Remarks<br />
1,3-Dichloro -5,5-<br />
dimethyl hydanto<strong>in</strong><br />
118-52-5<br />
0,2<br />
0,4<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
No support<strong>in</strong>g reference is suggested <strong>for</strong> this product.<br />
O<strong>the</strong>r reference(s)<br />
Pilipenko, A.T., Zui, O.V., Terletskaga, A.V.,"Chemilum<strong>in</strong>escence<br />
determ<strong>in</strong>ation of 1,3-dibromo-5,5-dimethylhydanto<strong>in</strong> and 1,3-dichloro-5,5-<br />
dimethylhydanto<strong>in</strong> <strong>in</strong> water and air" Zh. Anal. Khim., 41(4), p.705<br />
Dichloroacetylene<br />
7572-29-4<br />
--<br />
--<br />
0,39<br />
RP Activated charcoal tube 100/50 mg<br />
0,2 3 GC-FID<br />
OSHA<br />
IMIS0865<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
o-Dichlorobenzene<br />
95-50-1<br />
--<br />
--<br />
301<br />
RP SKC 226-01 activated charcoal tube<br />
Max: 10 GC-FID 150<br />
IRSST<br />
62-1<br />
2120 Activated charcoal 100/50 mg<br />
0,2<br />
p-Dichlorobenzene<br />
106-46-7<br />
120 C3 SKC 226-01 activated charcoal tube<br />
Max: 10<br />
2120 Activated charcoal 100/50 mg<br />
0,2 3<br />
GC-FID<br />
60<br />
IRSST<br />
37-1<br />
3,3'-Dichlorobenzid<strong>in</strong>e<br />
91-94-1<br />
Pc<br />
C2<br />
RP<br />
EM<br />
Glass fiber filter<br />
0,2 100 HPLC-UV<br />
NIOSH<br />
5509<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
1,4-Dichloro-2-butene<br />
764-41-0<br />
0,025 Pc<br />
C2<br />
EM<br />
Activated charcoal tube 400/200 mg<br />
0,2 24 GC-ECD<br />
OSHA<br />
07<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
OSHA method 07 is <strong>for</strong> organic vapours and can be adapted to this substance.<br />
Dichlorodifluoromethan<br />
e<br />
75-71-8<br />
4950 Two 400/200 mg et 100/50 mg activated 0,01- 4 GC-FID<br />
NIOSH<br />
1018<br />
charcoal tubes <strong>in</strong> series.<br />
0,05<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g. Freon 12.<br />
1,1-Dichloroethane<br />
75-34-3<br />
405<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
IRSST method 173-1 can be adapted to this product.<br />
1,2-Dichloroethane<br />
107-06-2<br />
4<br />
8<br />
C2<br />
EM<br />
SKC 226-01 activated charcoal tube<br />
2120 Activated charcoal 100/50 mg<br />
Max:<br />
0,2<br />
20<br />
10<br />
GC-FID<br />
8,1 5,0<br />
IRSST<br />
173-1<br />
1,2-dichloroethane must be specifically sampled due to a specific desorption<br />
solvent.