Substances non regulated from ROHS<br />
Yellow section <strong>in</strong> <strong>the</strong> orig<strong>in</strong>al document<br />
133<br />
Name<br />
CAS<br />
<strong>Sampl<strong>in</strong>g</strong> device<br />
Flow<br />
L/m<strong>in</strong><br />
Volume<br />
Pr<strong>in</strong>ciple<br />
MRV<br />
µg<br />
CVa<br />
%<br />
#<br />
meth.<br />
Remarks<br />
1-Bromopropane<br />
106-94-5<br />
SKC 226-01 activated charcoal tube<br />
2120 Activated charcoal 100/50 mg<br />
Max:<br />
0,2<br />
5<br />
GC-FID<br />
54 1,0<br />
IRSST<br />
333-1<br />
Acenaphtene<br />
83-32-9<br />
Glass fiber filter pretreated <strong>in</strong> <strong>the</strong><br />
laboratory, #Millipore AP4003705 <strong>in</strong><br />
series with an Orbo-42 tube #Supelco 2-<br />
0264<br />
2187 Orbo 42 100/50 mg<br />
911 GF filter-37<br />
2 960 GC-MS 0,12<br />
IRSST<br />
225-2<br />
The sampl<strong>in</strong>g tra<strong>in</strong> consists of a cassette that will collect <strong>the</strong> PAHs <strong>in</strong> particulate<br />
<strong>for</strong>m, followed by <strong>the</strong> sampl<strong>in</strong>g tube that will adsorb <strong>the</strong> PAHs <strong>in</strong> vapour <strong>for</strong>m.<br />
This tube is connected directly to <strong>the</strong> pump by Tygon tub<strong>in</strong>g. After sampl<strong>in</strong>g, <strong>the</strong><br />
samples must be stored <strong>in</strong> <strong>the</strong> freezer protected from light. The tubes and filters<br />
must be shipped toge<strong>the</strong>r. Ten hydrocarbons are determ<strong>in</strong>ed simultaneously:<br />
acenaph<strong>the</strong>ne, fluorene, phenanthrene, anthracene, fluoran<strong>the</strong>ne, pyrene,<br />
chrysene, benz(a)anthracene, benzo(e)pyrene et le benzo(a)pyrene.<br />
Anthracene 120-12-7<br />
Glass fiber filter pretreated <strong>in</strong> <strong>the</strong><br />
laboratory, #Millipore AP4003705 <strong>in</strong><br />
series with an Orbo-42 tube #Supelco 2-<br />
0264<br />
2187 Orbo 42 100/50 mg<br />
911 GF filter-37<br />
2 960 GC-MS 0,12<br />
IRSST<br />
225-2<br />
The sampl<strong>in</strong>g tra<strong>in</strong> consists of a cassette that will collect <strong>the</strong> PAHs <strong>in</strong> particulate<br />
<strong>for</strong>m, followed by <strong>the</strong> sampl<strong>in</strong>g tube that will adsorb <strong>the</strong> PAHs <strong>in</strong> vapour <strong>for</strong>m.<br />
This tube is connected directly to <strong>the</strong> pump by Tygon tub<strong>in</strong>g. After sampl<strong>in</strong>g, <strong>the</strong><br />
samples must be stored <strong>in</strong> <strong>the</strong> freezer protected from light. The tubes and filters<br />
must be shipped toge<strong>the</strong>r. Ten hydrocarbons are determ<strong>in</strong>ed simultaneously:<br />
acenaph<strong>the</strong>ne, fluorene, phenanthrene, anthracene, fluoran<strong>the</strong>ne, pyrene,<br />
chrysene, benz(a)anthracene, benzo(e)pyrene et le benzo(a)pyrene.<br />
Bacteria (Culture)<br />
Trypticase soy agar<br />
5560 Agar-TSA bacteria agar<br />
28 140 DLM-GC<br />
IRSST<br />
341<br />
The sampl<strong>in</strong>g volumes are between 56 and 140 litres. For surface wipe sampl<strong>in</strong>g,<br />
contact Laboratory Customer Service.<br />
Bacterial identification.<br />
Bacteria (Culture)<br />
Trypticase soy agar<br />
5560 Agar-TSA bacteria agar<br />
28 140 SM<br />
IRSST<br />
264<br />
The sampl<strong>in</strong>g volumes are between 56 and 140 litres.<br />
Bacterial counts.<br />
Bacteria (Culture)<br />
Polycarbonate filter 0.8 µm<br />
930 Polycarbonate filter<br />
2 60 DLM-GC<br />
IRSST<br />
341<br />
The sampl<strong>in</strong>g volumes are between 20 and 60 litres.<br />
For sampl<strong>in</strong>g an environment with concentrations above 10,000 CFU/m³ of air.<br />
Bacterial identification.<br />
Bacteria (Culture)<br />
Polycarbonate filter 0.8µm<br />
930 Polycarbonate filter<br />
2 40 SM<br />
22<br />
IRSST<br />
368<br />
For sampl<strong>in</strong>g an environment with concentrations above 10,000 CFU/m³ of air.<br />
Bacterial counts. The MRV is 1600 CFU/m³.<br />
Benzo(e)pyrene 192-97-2<br />
Millipore AP4003705 glass fiber filter<br />
pretreated <strong>in</strong> <strong>the</strong> laboratory <strong>in</strong> series with<br />
a Supelco 2-0264 Orbo-42 tube<br />
2187 Orbo 42 100/50 mg<br />
911 GF filter-37<br />
2 960 GC-MS 0,09<br />
IRSST<br />
225-2<br />
The sampl<strong>in</strong>g tra<strong>in</strong> consists of a cassette that will collect <strong>the</strong> PAHs <strong>in</strong> particulate<br />
<strong>for</strong>m, followed by a tube that will adsorb <strong>the</strong> PAHs <strong>in</strong> vapour <strong>for</strong>m. This tube is<br />
connected directly to <strong>the</strong> pump by Tygon tub<strong>in</strong>g. After sampl<strong>in</strong>g, <strong>the</strong> samples<br />
must be stored <strong>in</strong> <strong>the</strong> freezer protected from light. The tubes and filters must be<br />
shipped toge<strong>the</strong>r. Ten hydrocarbons are determ<strong>in</strong>ed simultaneously:<br />
acenaph<strong>the</strong>ne, fluorene, phenanthrene, anthracene, fluoran<strong>the</strong>ne, pyrene,<br />
chrysene, benz(a)anthracene, benzo(e)pyrene et le benzo(a)pyrene.<br />
Butyraldehyde 123-72-8<br />
Supelco 2-0257 Orbo 23 tube<br />
2186 Orbo 23 120/60 mg<br />
0,1 10 GC-MS 0,1<br />
IRSST<br />
324-1<br />
Be<strong>for</strong>e and after sampl<strong>in</strong>g, tubes must be stored <strong>in</strong> a freezer.<br />
Eleven aldehydes are determ<strong>in</strong>ed simultaneously: acetaldehyde,<br />
isobutyraldehyde, isovaleraldehyde, propionaldehyde, butyraldehyde, furfural,<br />
heptanal, hexanal, valeraldehyde, acrole<strong>in</strong>e and <strong>for</strong>maldehyde. This method must<br />
not be used <strong>for</strong> <strong>the</strong> specific evaluation of <strong>for</strong>maldehyde; <strong>the</strong> methods to be used<br />
<strong>in</strong> this case are 295-1 and 357-1.