Sampling Guide for Air Contaminants in the Workplace - Irsst
Sampling Guide for Air Contaminants in the Workplace - Irsst
Sampling Guide for Air Contaminants in the Workplace - Irsst
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
ROHS Substances table<br />
45<br />
ROHS Name<br />
CAS<br />
TWAEV<br />
STEV<br />
Ceil<strong>in</strong>g<br />
(mg/m³)<br />
Notes<br />
<strong>Sampl<strong>in</strong>g</strong><br />
Device<br />
Flow<br />
L/m<strong>in</strong><br />
Volume<br />
TWAEV<br />
STEV<br />
(L)<br />
Pr<strong>in</strong>ciple<br />
MRV<br />
µg<br />
CVa<br />
(%)<br />
#<br />
meth.<br />
Remarks<br />
Ammonium chloride<br />
fume<br />
12125-02-9<br />
10<br />
20<br />
SKC 225-8-01-1 or 225-8-04 polyv<strong>in</strong>yl<br />
chloride filter<br />
902 PVC filter-37<br />
914 PVC filter-25<br />
1,5 Grav 25 4,9<br />
180 IRSST<br />
48-1<br />
Additional <strong>in</strong><strong>for</strong>mation is available <strong>in</strong> Info-Labo 91-03. The weight measurement<br />
method <strong>for</strong> dusts is by def<strong>in</strong>ition non-specific.<br />
Ammonium chloride<br />
fume<br />
10<br />
20<br />
Mixed cellulose ester filter<br />
2 960 IC-CD<br />
30<br />
OSHA<br />
ID188<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
12125-02-9<br />
Ammonium<br />
perfluorooctanoate<br />
3825-26-1<br />
0,1 Pc<br />
Mixed cellulose ester filter <strong>in</strong> series with a<br />
glass midget imp<strong>in</strong>ger conta<strong>in</strong><strong>in</strong>g methanol<br />
GC-ECD<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
O<strong>the</strong>r reference(s)<br />
Belisle, J. and Hagen, D.F. "A method <strong>for</strong> <strong>the</strong> determ<strong>in</strong>ation of<br />
perfluorooctanoic acid <strong>in</strong> blood and o<strong>the</strong>r biological samples",Analytical<br />
biochemistry 101, 369-376<br />
Ubel, F.A., Sorenson, S.D. and Roach, D.E. "Health status of plant worker<br />
exposed to fluorochemicals a prelim<strong>in</strong>ary report ", Ind. Hyg Assoc J. (41) Août<br />
1980<br />
Ammonium sulfamate<br />
7773-06-0<br />
10 Mixed cellulose ester filter<br />
2 960 IC-CD<br />
30<br />
OSHA<br />
ID188<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Ammonium sulfamate<br />
7773-06-0<br />
10 SKC 225-8-01-1 or 225-8-04 polyv<strong>in</strong>yl 1,5 180 Grav 25 4,9 IRSST<br />
48-1<br />
chloride filter<br />
902 PVC filter-37<br />
914 PVC filter-25<br />
Additional <strong>in</strong><strong>for</strong>mation is available <strong>in</strong> Info-Labo 91-03. The weight measurement<br />
method <strong>for</strong> dusts is by def<strong>in</strong>ition non-specific.<br />
Anil<strong>in</strong>e<br />
62-53-3<br />
7,6 Pc Impregnated glass fiber filter, # Millipore 1 15 HPLC-MS 6<br />
IRSST<br />
363<br />
AP4003705<br />
955 Impregned FGF<br />
Anil<strong>in</strong>e, diethanolam<strong>in</strong>e, dimethylam<strong>in</strong>e, ethanolam<strong>in</strong>e, isopropylam<strong>in</strong>e,<br />
methylam<strong>in</strong>e and morphol<strong>in</strong>e can be sampled at <strong>the</strong> same time.<br />
o-Anisid<strong>in</strong>e<br />
90-04-0<br />
0,5 Pc<br />
C3<br />
XAD-2 tube 150/75 mg<br />
0,5-1 225 HPLC-UV<br />
NIOSH<br />
2514<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
p-Anisid<strong>in</strong>e<br />
104-94-9<br />
0,5 Pc XAD-2 tube 150/75 mg<br />
0,5-1 225 HPLC-UV<br />
NIOSH<br />
2514<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.