ROHS Substances table<br />

53<br />

ROHS Name<br />

CAS<br />

TWAEV<br />

STEV<br />

Ceil<strong>in</strong>g<br />

(mg/m³)<br />

Notes<br />

<strong>Sampl<strong>in</strong>g</strong><br />

Device<br />

Flow<br />

L/m<strong>in</strong><br />

Volume<br />

TWAEV<br />

STEV<br />

(L)<br />

Pr<strong>in</strong>ciple<br />

MRV<br />

µg<br />

CVa<br />

(%)<br />

#<br />

meth.<br />

Remarks<br />

sec-Butyl acetate<br />

105-46-4<br />

950 0,0286 GC-FID 475<br />

IRSST<br />

274-1<br />

3M 3500 organic vapour monitor<br />

2695 Passive dosimeter<br />

For <strong>the</strong> monitors, <strong>the</strong> flow must be considered as be<strong>in</strong>g a sampl<strong>in</strong>g rate.<br />

Accord<strong>in</strong>g to <strong>the</strong> data from 3M, <strong>the</strong> precision (CVsampl<strong>in</strong>g) of <strong>the</strong> sampl<strong>in</strong>g rate is<br />

5%. Refer to <strong>the</strong> 3M passive monitor guide on <strong>the</strong> IRSST's Web site.<br />

sec-Butyl acetate<br />

105-46-4<br />

950 SKC 226-01 activated charcoal tube<br />

Max: 10 GC-FID 475<br />

IRSST<br />

274-1<br />

2120 Activated charcoal 100/50 mg<br />

0,2<br />

The analysis can be done by gas chromatography coupled with mass<br />

spectrometry (GC-MS, IRSST method #369); <strong>in</strong> this case <strong>the</strong> analytical<br />

uncerta<strong>in</strong>ty (CVa) is 1.1%.<br />

tert-Butyl acetate<br />

540-88-5<br />

950 SKC 226-01 activated charcoal tube<br />

Max: 10 GC-FID 475<br />

IRSST<br />

275-1<br />

2120 Activated charcoal 100/50 mg<br />

0,2<br />

n-Butyl acrylate<br />

141-32-2<br />

10 Activated charcoal tube impregnated with 0,05 12 GC-FID<br />

OSHA<br />

PV2011<br />

4-tert-butylcatechol<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

n-Butyl alcohol<br />

71-36-3<br />

--<br />

--<br />

152<br />

Pc<br />

RP<br />

SKC 226-01 activated charcoal tube<br />

2120 Activated charcoal 100/50 mg<br />

Max:<br />

0,2<br />

10 GC-FID 81 5,0 IRSST<br />

90-1<br />

The analysis can be done by gas chromatography coupled with mass<br />

spectrometry (GC-MS, IRSST method #369); <strong>in</strong> this case <strong>the</strong> analytical<br />

uncerta<strong>in</strong>ty (CVa) is 2.1%.<br />

n-Butyl alcohol<br />

71-36-3<br />

--<br />

--<br />

152<br />

Pc<br />

RP<br />

3M 3500 organic vapour monitor<br />

2695 Passive dosimeter<br />

0,0343 GC-FID 81 5,0<br />

IRSST<br />

90-1<br />

For <strong>the</strong> monitors, <strong>the</strong> flow must be considered as be<strong>in</strong>g a sampl<strong>in</strong>g rate.<br />

Accord<strong>in</strong>g to <strong>the</strong> data from 3M, <strong>the</strong> precision (CVsampl<strong>in</strong>g) of <strong>the</strong> sampl<strong>in</strong>g rate is<br />

2.0%. Refer to <strong>the</strong> 3M passive monitor guide on <strong>the</strong> IRSST's Web site.<br />

sec-Butyl alcohol<br />

78-92-2<br />

303 SKC 226-01 activated charcoal tube<br />

Max: 10 GC-FID 65 1,0 IRSST<br />

276-2<br />

2120 Activated charcoal 100/50 mg<br />

0,2<br />

tert-Butyl alcohol<br />

75-65-0<br />

303 SKC 226-01 activated charcoal tube<br />

Max: 10<br />

2120 Activated charcoal 100/50 mg<br />

0,2 3<br />

GC-FID<br />

150<br />

IRSST<br />

277-1<br />

tert-Butyl chromate (as<br />

CrO3)<br />

1189-85-1<br />

--<br />

--<br />

0,1<br />

Pc<br />

RP<br />

PALL CA28149-306 v<strong>in</strong>yl/acrylic<br />

copolymer filter<br />

926 V<strong>in</strong>yl/acrylic copolymer filter<br />

1,5 à 4 IC-VIS<br />

360 IRSST<br />

365<br />

IRSST method #365 could be adapted <strong>for</strong> this product. Contact <strong>the</strong> IRSST be<strong>for</strong>e<br />

sampl<strong>in</strong>g.