Sampling Guide for Air Contaminants in the Workplace - Irsst
Sampling Guide for Air Contaminants in the Workplace - Irsst
Sampling Guide for Air Contaminants in the Workplace - Irsst
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
ROHS Substances table<br />
53<br />
ROHS Name<br />
CAS<br />
TWAEV<br />
STEV<br />
Ceil<strong>in</strong>g<br />
(mg/m³)<br />
Notes<br />
<strong>Sampl<strong>in</strong>g</strong><br />
Device<br />
Flow<br />
L/m<strong>in</strong><br />
Volume<br />
TWAEV<br />
STEV<br />
(L)<br />
Pr<strong>in</strong>ciple<br />
MRV<br />
µg<br />
CVa<br />
(%)<br />
#<br />
meth.<br />
Remarks<br />
sec-Butyl acetate<br />
105-46-4<br />
950 0,0286 GC-FID 475<br />
IRSST<br />
274-1<br />
3M 3500 organic vapour monitor<br />
2695 Passive dosimeter<br />
For <strong>the</strong> monitors, <strong>the</strong> flow must be considered as be<strong>in</strong>g a sampl<strong>in</strong>g rate.<br />
Accord<strong>in</strong>g to <strong>the</strong> data from 3M, <strong>the</strong> precision (CVsampl<strong>in</strong>g) of <strong>the</strong> sampl<strong>in</strong>g rate is<br />
5%. Refer to <strong>the</strong> 3M passive monitor guide on <strong>the</strong> IRSST's Web site.<br />
sec-Butyl acetate<br />
105-46-4<br />
950 SKC 226-01 activated charcoal tube<br />
Max: 10 GC-FID 475<br />
IRSST<br />
274-1<br />
2120 Activated charcoal 100/50 mg<br />
0,2<br />
The analysis can be done by gas chromatography coupled with mass<br />
spectrometry (GC-MS, IRSST method #369); <strong>in</strong> this case <strong>the</strong> analytical<br />
uncerta<strong>in</strong>ty (CVa) is 1.1%.<br />
tert-Butyl acetate<br />
540-88-5<br />
950 SKC 226-01 activated charcoal tube<br />
Max: 10 GC-FID 475<br />
IRSST<br />
275-1<br />
2120 Activated charcoal 100/50 mg<br />
0,2<br />
n-Butyl acrylate<br />
141-32-2<br />
10 Activated charcoal tube impregnated with 0,05 12 GC-FID<br />
OSHA<br />
PV2011<br />
4-tert-butylcatechol<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
n-Butyl alcohol<br />
71-36-3<br />
--<br />
--<br />
152<br />
Pc<br />
RP<br />
SKC 226-01 activated charcoal tube<br />
2120 Activated charcoal 100/50 mg<br />
Max:<br />
0,2<br />
10 GC-FID 81 5,0 IRSST<br />
90-1<br />
The analysis can be done by gas chromatography coupled with mass<br />
spectrometry (GC-MS, IRSST method #369); <strong>in</strong> this case <strong>the</strong> analytical<br />
uncerta<strong>in</strong>ty (CVa) is 2.1%.<br />
n-Butyl alcohol<br />
71-36-3<br />
--<br />
--<br />
152<br />
Pc<br />
RP<br />
3M 3500 organic vapour monitor<br />
2695 Passive dosimeter<br />
0,0343 GC-FID 81 5,0<br />
IRSST<br />
90-1<br />
For <strong>the</strong> monitors, <strong>the</strong> flow must be considered as be<strong>in</strong>g a sampl<strong>in</strong>g rate.<br />
Accord<strong>in</strong>g to <strong>the</strong> data from 3M, <strong>the</strong> precision (CVsampl<strong>in</strong>g) of <strong>the</strong> sampl<strong>in</strong>g rate is<br />
2.0%. Refer to <strong>the</strong> 3M passive monitor guide on <strong>the</strong> IRSST's Web site.<br />
sec-Butyl alcohol<br />
78-92-2<br />
303 SKC 226-01 activated charcoal tube<br />
Max: 10 GC-FID 65 1,0 IRSST<br />
276-2<br />
2120 Activated charcoal 100/50 mg<br />
0,2<br />
tert-Butyl alcohol<br />
75-65-0<br />
303 SKC 226-01 activated charcoal tube<br />
Max: 10<br />
2120 Activated charcoal 100/50 mg<br />
0,2 3<br />
GC-FID<br />
150<br />
IRSST<br />
277-1<br />
tert-Butyl chromate (as<br />
CrO3)<br />
1189-85-1<br />
--<br />
--<br />
0,1<br />
Pc<br />
RP<br />
PALL CA28149-306 v<strong>in</strong>yl/acrylic<br />
copolymer filter<br />
926 V<strong>in</strong>yl/acrylic copolymer filter<br />
1,5 à 4 IC-VIS<br />
360 IRSST<br />
365<br />
IRSST method #365 could be adapted <strong>for</strong> this product. Contact <strong>the</strong> IRSST be<strong>for</strong>e<br />
sampl<strong>in</strong>g.