Sampling Guide for Air Contaminants in the Workplace - Irsst
Sampling Guide for Air Contaminants in the Workplace - Irsst
Sampling Guide for Air Contaminants in the Workplace - Irsst
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
ROHS Substances table<br />
96<br />
ROHS Name<br />
CAS<br />
TWAEV<br />
STEV<br />
Ceil<strong>in</strong>g<br />
(mg/m³)<br />
Notes<br />
<strong>Sampl<strong>in</strong>g</strong><br />
Device<br />
Flow<br />
L/m<strong>in</strong><br />
Volume<br />
TWAEV<br />
STEV<br />
(L)<br />
Pr<strong>in</strong>ciple<br />
MRV<br />
µg<br />
CVa<br />
(%)<br />
#<br />
meth.<br />
Remarks<br />
Methyl amyl alcohol<br />
108-11-2<br />
104<br />
167<br />
Pc Activated charcoal tube 100/50 mg<br />
0,01 10<br />
à 0,2 3<br />
GC-FID<br />
NIOSH<br />
1405<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Methyl n-amyl ketone<br />
110-43-0<br />
233 SKC 226-01 activated charcoal tube<br />
Max: 10 GC-FID 49 2,6 IRSST<br />
316-1<br />
2120 Activated charcoal 100/50 mg<br />
0,2<br />
The analysis can be done by gas chromatography coupled with mass<br />
spectrometry (GC-MS, IRSST method #369); <strong>in</strong> this case <strong>the</strong> analytical<br />
uncerta<strong>in</strong>ty (CVa) is 1.1%.<br />
Methyl bromide<br />
74-83-9<br />
19 Pc Two Anasorb 747 tubes<br />
0,05- 3 GC-FID<br />
OSHA<br />
PV2040<br />
0,2<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g. Immediate refrigeration after sampl<strong>in</strong>g.<br />
Methyl tert-butyl e<strong>the</strong>r<br />
1634-04-4<br />
144 Two 400/200 mg activated charcoal tubes 0,1-0,2 96 GC-FID<br />
NIOSH<br />
1615<br />
<strong>in</strong> series<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Methyl n-butyl ketone<br />
591-78-6<br />
20 Pc Activated charcoal tube 100/50mg<br />
0,01- 10 GC-FID<br />
NIOSH<br />
1300<br />
0,2<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Methyl chloride<br />
74-87-3<br />
103<br />
207<br />
Pc Two 100/50 mg activated charcoal tubes 0,01- 3<br />
<strong>in</strong> series<br />
0,1 1,5<br />
GC-FID<br />
NIOSH<br />
1001<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Methyl chloro<strong>for</strong>m<br />
71-55-6<br />
1910<br />
2460<br />
SKC 226-01 activated charcoal tube<br />
2120 Activated charcoal 100/50 mg<br />
Max:<br />
0,2<br />
6<br />
3<br />
GC-FID<br />
450 6,4<br />
IRSST<br />
100-1<br />
Methyl chloro<strong>for</strong>m<br />
71-55-6<br />
1910<br />
2460<br />
3M 3500 organic vapour monitor<br />
2695 Passive dosimeter<br />
0,0309 GC-FID 450 6,4<br />
IRSST<br />
100-1<br />
For <strong>the</strong> monitors, <strong>the</strong> flow must be considered as be<strong>in</strong>g a sampl<strong>in</strong>g rate.<br />
Accord<strong>in</strong>g to <strong>the</strong> data from 3M, <strong>the</strong> precision (CVsampl<strong>in</strong>g) of <strong>the</strong> sampl<strong>in</strong>g rate is<br />
1.0%. Refer to <strong>the</strong> 3M passive monitor guide on <strong>the</strong> IRSST's Web site.<br />
Methyl 2-cyanoacrylate<br />
137-05-3<br />
9,1<br />
18<br />
XAD-7 tube impregnated with phosphoric<br />
acid<br />
0,1 12 HPLC-UV<br />
1,5<br />
OSHA<br />
55<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Alcohols, free radicals or o<strong>the</strong>r substances likely to react with methyl 2-<br />
cyanoacrylate may cause <strong>in</strong>terference.<br />
Methyl demeton<br />
8022-00-2<br />
0,5 Pc XAD-2 tube <strong>in</strong> series with a mixed<br />
0,2-1 200 GC-FPD<br />
NIOSH<br />
5514<br />
cellulose ester filter<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
NIOSH method 5514 is <strong>for</strong> demeton® and can be adapted to methyl demeton.