ROHS Substances table<br />

96<br />

ROHS Name<br />

CAS<br />

TWAEV<br />

STEV<br />

Ceil<strong>in</strong>g<br />

(mg/m³)<br />

Notes<br />

<strong>Sampl<strong>in</strong>g</strong><br />

Device<br />

Flow<br />

L/m<strong>in</strong><br />

Volume<br />

TWAEV<br />

STEV<br />

(L)<br />

Pr<strong>in</strong>ciple<br />

MRV<br />

µg<br />

CVa<br />

(%)<br />

#<br />

meth.<br />

Remarks<br />

Methyl amyl alcohol<br />

108-11-2<br />

104<br />

167<br />

Pc Activated charcoal tube 100/50 mg<br />

0,01 10<br />

à 0,2 3<br />

GC-FID<br />

NIOSH<br />

1405<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Methyl n-amyl ketone<br />

110-43-0<br />

233 SKC 226-01 activated charcoal tube<br />

Max: 10 GC-FID 49 2,6 IRSST<br />

316-1<br />

2120 Activated charcoal 100/50 mg<br />

0,2<br />

The analysis can be done by gas chromatography coupled with mass<br />

spectrometry (GC-MS, IRSST method #369); <strong>in</strong> this case <strong>the</strong> analytical<br />

uncerta<strong>in</strong>ty (CVa) is 1.1%.<br />

Methyl bromide<br />

74-83-9<br />

19 Pc Two Anasorb 747 tubes<br />

0,05- 3 GC-FID<br />

OSHA<br />

PV2040<br />

0,2<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g. Immediate refrigeration after sampl<strong>in</strong>g.<br />

Methyl tert-butyl e<strong>the</strong>r<br />

1634-04-4<br />

144 Two 400/200 mg activated charcoal tubes 0,1-0,2 96 GC-FID<br />

NIOSH<br />

1615<br />

<strong>in</strong> series<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Methyl n-butyl ketone<br />

591-78-6<br />

20 Pc Activated charcoal tube 100/50mg<br />

0,01- 10 GC-FID<br />

NIOSH<br />

1300<br />

0,2<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Methyl chloride<br />

74-87-3<br />

103<br />

207<br />

Pc Two 100/50 mg activated charcoal tubes 0,01- 3<br />

<strong>in</strong> series<br />

0,1 1,5<br />

GC-FID<br />

NIOSH<br />

1001<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Methyl chloro<strong>for</strong>m<br />

71-55-6<br />

1910<br />

2460<br />

SKC 226-01 activated charcoal tube<br />

2120 Activated charcoal 100/50 mg<br />

Max:<br />

0,2<br />

6<br />

3<br />

GC-FID<br />

450 6,4<br />

IRSST<br />

100-1<br />

Methyl chloro<strong>for</strong>m<br />

71-55-6<br />

1910<br />

2460<br />

3M 3500 organic vapour monitor<br />

2695 Passive dosimeter<br />

0,0309 GC-FID 450 6,4<br />

IRSST<br />

100-1<br />

For <strong>the</strong> monitors, <strong>the</strong> flow must be considered as be<strong>in</strong>g a sampl<strong>in</strong>g rate.<br />

Accord<strong>in</strong>g to <strong>the</strong> data from 3M, <strong>the</strong> precision (CVsampl<strong>in</strong>g) of <strong>the</strong> sampl<strong>in</strong>g rate is<br />

1.0%. Refer to <strong>the</strong> 3M passive monitor guide on <strong>the</strong> IRSST's Web site.<br />

Methyl 2-cyanoacrylate<br />

137-05-3<br />

9,1<br />

18<br />

XAD-7 tube impregnated with phosphoric<br />

acid<br />

0,1 12 HPLC-UV<br />

1,5<br />

OSHA<br />

55<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Alcohols, free radicals or o<strong>the</strong>r substances likely to react with methyl 2-<br />

cyanoacrylate may cause <strong>in</strong>terference.<br />

Methyl demeton<br />

8022-00-2<br />

0,5 Pc XAD-2 tube <strong>in</strong> series with a mixed<br />

0,2-1 200 GC-FPD<br />

NIOSH<br />

5514<br />

cellulose ester filter<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

NIOSH method 5514 is <strong>for</strong> demeton® and can be adapted to methyl demeton.