ROHS Substances table<br />

46<br />

ROHS Name<br />

CAS<br />

TWAEV<br />

STEV<br />

Ceil<strong>in</strong>g<br />

(mg/m³)<br />

Notes<br />

<strong>Sampl<strong>in</strong>g</strong><br />

Device<br />

Flow<br />

L/m<strong>in</strong><br />

Volume<br />

TWAEV<br />

STEV<br />

(L)<br />

Pr<strong>in</strong>ciple<br />

MRV<br />

µg<br />

CVa<br />

(%)<br />

#<br />

meth.<br />

Remarks<br />

Antimony [7440-36-0],<br />

metal and compounds<br />

(as Sb)<br />

0,5 Omega M-083700AF or Omega M-<br />

1,5 180 FAAS 10<br />

IRSST<br />

55-2<br />

082500AFP mixed cellulose ester filter<br />

905 MCE filter-37<br />

915 MCE filter-25<br />

Specific sampl<strong>in</strong>g must be carried out <strong>for</strong> this substance.<br />

The analytical results are expressed as total antimony.<br />

Antimony trioxide (as<br />

Sb)<br />

1309-64-4<br />

0,5 C3 Omega M-083700AF or Omega M-<br />

1,5 180 FAAS 10<br />

IRSST<br />

55-2<br />

082500AFP mixed cellulose ester filter<br />

905 MCE filter-37<br />

915 MCE filter-25<br />

Specific sampl<strong>in</strong>g must be carried out <strong>for</strong> this substance.<br />

The analytical results are expressed as total antimony.<br />

Antimony trioxide,<br />

production (as Sb)<br />

1309-64-4<br />

C2<br />

RP<br />

EM<br />

Omega M-083700AF or Omega M-<br />

082500AFP mixed cellulose ester filter<br />

905 MCE filter-37<br />

915 MCE filter-25<br />

1,5 180 FAAS 10<br />

IRSST<br />

55-2<br />

Specific sampl<strong>in</strong>g must be carried out <strong>for</strong> this substance.<br />

The analytical results are expressed as total antimony.<br />

ANTU (alpha-<br />

Naphthylthiourea)<br />

86-88-4<br />

0,3 Polytetrafluorocarbon (teflon) filter<br />

1,5-2 480 HPLC-UV<br />

NIOSH<br />

S276<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Argon<br />

7440-37-1<br />

Ax<br />

DRI-elec<br />

IRSST<br />

26-C<br />

S<strong>in</strong>ce argon is a simple asphyxiant, <strong>the</strong> field method <strong>for</strong> determ<strong>in</strong>ation of oxygen<br />

<strong>in</strong> air is done with a direct-read<strong>in</strong>g <strong>in</strong>strument (DRI).<br />

The m<strong>in</strong>imum reported value is 1% oxygen. The reference method corresponds<br />

to calibration of <strong>the</strong> DRI.<br />

Arsenic, elemental<br />

[7440-38-2], and<br />

<strong>in</strong>organic compounds<br />

(except Ars<strong>in</strong>e) (as As)<br />

0,1 Mixed cellulose ester filter<br />

1-4 ICP<br />

NIOSH<br />

7300<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g. The recommended sampl<strong>in</strong>g volume is 5 to<br />

2000 litres.<br />

Arsenic trioxide,<br />

production<br />

1327-53-3<br />

C2<br />

RP<br />

EM<br />

Mixed cellulose ester filter followed by a<br />

cellulose pad impregnated with sodium<br />

carbonate and glycerol.<br />

1-3 1000 FAAS<br />

NIOSH<br />

7901<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

There is no reference value <strong>for</strong> <strong>the</strong> standard, but measurement could be required<br />

none<strong>the</strong>less by target<strong>in</strong>g <strong>the</strong> lowest possible limit of detection, given <strong>the</strong> C2<br />

carcenogenicity notation.<br />

Ars<strong>in</strong>e<br />

7784-42-1<br />

0,16 Activated charcoal tube 100/50 mg<br />

0,01- 10 ET-AAS<br />

NIOSH<br />

6001<br />

0,2<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g. Stable <strong>for</strong> 6 days at 25°C.<br />

The different arsenic compounts can <strong>in</strong>terfere with ars<strong>in</strong>e. An MCE filter place<br />

be<strong>for</strong>e <strong>the</strong> tube can remove <strong>the</strong> aerosols.