07.03.2014 Views

Sampling Guide for Air Contaminants in the Workplace - Irsst

Sampling Guide for Air Contaminants in the Workplace - Irsst

Sampling Guide for Air Contaminants in the Workplace - Irsst

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ROHS Substances table<br />

125<br />

ROHS Name<br />

CAS<br />

TWAEV<br />

STEV<br />

Ceil<strong>in</strong>g<br />

(mg/m³)<br />

Notes<br />

<strong>Sampl<strong>in</strong>g</strong><br />

Device<br />

Flow<br />

L/m<strong>in</strong><br />

Volume<br />

TWAEV<br />

STEV<br />

(L)<br />

Pr<strong>in</strong>ciple<br />

MRV<br />

µg<br />

CVa<br />

(%)<br />

#<br />

meth.<br />

Remarks<br />

o-Tolid<strong>in</strong>e<br />

119-93-7<br />

Pc<br />

C2<br />

RP<br />

EM<br />

Two glass fiber filters impregnated with<br />

sulfuric acid<br />

1 100 GC-ECD<br />

OSHA<br />

71<br />

The filters must be transferred to vials conta<strong>in</strong><strong>in</strong>g deionized water with<strong>in</strong> 10 hours<br />

of sampl<strong>in</strong>g. Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Any compound that reacts with <strong>the</strong> sulfuric acid on <strong>the</strong> filters may cause<br />

<strong>in</strong>terference.<br />

Toluene<br />

108-88-3<br />

188 Pc 3M 3500 organic vapour monitor<br />

0,0314 GC-FID 20 3,0 IRSST<br />

16-2<br />

2695 Passive dosimeter<br />

For <strong>the</strong> monitors, <strong>the</strong> flow must be considered as be<strong>in</strong>g a sampl<strong>in</strong>g rate.<br />

Accord<strong>in</strong>g to <strong>the</strong> data from 3M, <strong>the</strong> precision (CVsampl<strong>in</strong>g) of <strong>the</strong> sampl<strong>in</strong>g rate is<br />

1.9%. Refer to <strong>the</strong> 3M passive monitor guide on <strong>the</strong> IRSST's Web site.<br />

Toluene<br />

108-88-3<br />

188 Pc SKC 226-01 activated charcoal tube<br />

Max: 5 GC-FID 20 3,0 IRSST<br />

16-2<br />

2120 Activated charcoal 100/50 mg<br />

0,2<br />

The analysis can be done by gas chromatography coupled with mass<br />

spectrometry (GC-MS, IRSST method #369); <strong>in</strong> this case <strong>the</strong> analytical<br />

uncerta<strong>in</strong>ty (CVa) is 0.56%.<br />

Toluene diisocyanate<br />

(TDI) (isomers mixture)<br />

26471-62-5<br />

0,036<br />

0,14<br />

EM<br />

S<br />

Impregnated glass fiber filter<br />

970 Impregnated GFF<br />

1,0 HPLC-MS 0,0006<br />

15 IRSST<br />

366<br />

The recommended volume is 15 litres; however <strong>the</strong> sampl<strong>in</strong>g time can be up to 8<br />

hours. Store <strong>the</strong> samples <strong>in</strong> a refrigerator be<strong>for</strong>e and after sampl<strong>in</strong>g.<br />

Five isocyanates can be requested at <strong>the</strong> same time: HDI, TDI, MDI, IPDI and<br />

HMDI. The analysis is done <strong>for</strong> <strong>the</strong> isocyanates present <strong>in</strong> vapour <strong>for</strong>m only and<br />

<strong>the</strong> result is expressed as a monomer concentration.<br />

Toluene diisocyanate<br />

(TDI) (isomers mixture)<br />

26471-62-5<br />

0,036<br />

0,14<br />

EM<br />

S<br />

Millipore AP4003705 glass fiber filter<br />

pretreated <strong>in</strong> <strong>the</strong> laboratory <strong>in</strong> series with<br />

a Teflon filter #MSI Z50WP03700<br />

917 PTF filter<br />

GF filter<br />

Vial<br />

1 HPLC-UV- 0,03<br />

Flu<br />

15 IRSST<br />

376<br />

Refer to <strong>the</strong> sampl<strong>in</strong>g guidel<strong>in</strong>es supplied with <strong>the</strong> equipment. If more than one<br />

isocyanate is requested, provide a process sample. For surface wipe sampl<strong>in</strong>g,<br />

contact Laboratory Customer Service.<br />

The two filters <strong>in</strong> <strong>the</strong> sampl<strong>in</strong>g cassette allow specific analysis of monomer TDI <strong>in</strong><br />

vapour <strong>for</strong>m and <strong>in</strong> aerosol <strong>for</strong>m. The result supplied <strong>in</strong> <strong>the</strong> report is <strong>the</strong> sum of<br />

<strong>the</strong> monomers of TDI of <strong>the</strong> two fractions. Determ<strong>in</strong>ation of <strong>the</strong> correspond<strong>in</strong>g<br />

oligomers is also done dur<strong>in</strong>g <strong>the</strong> analysis. The sampl<strong>in</strong>g time can be longer than<br />

15 m<strong>in</strong>utes if <strong>the</strong> TDI is present <strong>in</strong> vapour <strong>for</strong>m only.<br />

o-Toluid<strong>in</strong>e<br />

95-53-4<br />

8,8 Pc<br />

C2<br />

RP<br />

EM<br />

Two glass fiber filters impregnated with<br />

sulfuric acid<br />

1 100 GC-ECD<br />

OSHA<br />

73<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

.<br />

Any compound that reacts with <strong>the</strong> sulfuric acid may cause <strong>in</strong>terference.<br />

m-Toluid<strong>in</strong>e<br />

108-44-1<br />

8,8 Pc Two glass fiber filters impregnated with 1 100 GC-ECD<br />

OSHA<br />

73<br />

sulfuric acid<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

.<br />

All compounds that can react with sulfuric acid can cause <strong>in</strong>terference.<br />

p-Toluid<strong>in</strong>e<br />

106-49-0<br />

8,8 Pc<br />

C2<br />

EM<br />

Two glass fiber filters impregnated with<br />

sulfuric acid.<br />

1 960 GC-ECD<br />

OSHA<br />

73<br />

Keeps <strong>for</strong> at least 15 days at 21°C. Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

All compounds that can react with sulfuric acid can cause <strong>in</strong>terference.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!