ROHS Substances table<br />

83<br />

ROHS Name<br />

CAS<br />

TWAEV<br />

STEV<br />

Ceil<strong>in</strong>g<br />

(mg/m³)<br />

Notes<br />

<strong>Sampl<strong>in</strong>g</strong><br />

Device<br />

Flow<br />

L/m<strong>in</strong><br />

Volume<br />

TWAEV<br />

STEV<br />

(L)<br />

Pr<strong>in</strong>ciple<br />

MRV<br />

µg<br />

CVa<br />

(%)<br />

#<br />

meth.<br />

Remarks<br />

Gasol<strong>in</strong>e<br />

8006-61-9<br />

890<br />

1480<br />

C3 SKC 226-01 activated charcoal tube<br />

Max: 10<br />

2120 Activated charcoal 100/50 mg<br />

0,2 3<br />

GC-FID<br />

450 1,0<br />

IRSST<br />

304-1<br />

Germanium tetrahydride<br />

7782-65-2<br />

0,63 Activated charcoal tube 100/50 mg<br />

0,2 48 ET-AAS<br />

OSHA<br />

IMIS1360<br />

A mixed cellulose ester filter can be considered preced<strong>in</strong>g <strong>the</strong> activated charcoal<br />

tube to elim<strong>in</strong>ate <strong>the</strong> germanium compounds present as aerosol. Contact <strong>the</strong><br />

IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Glutaraldehyde<br />

111-30-8<br />

--<br />

--<br />

0,41<br />

RP<br />

S<br />

Two glass fiber filters #SKC 227-5<br />

impregnated with 2,4-<br />

d<strong>in</strong>itrophenylhydraz<strong>in</strong>e (DNPH) and<br />

phosphoric acid.<br />

921 GF Filter-DNPH-37<br />

1 15 HPLC-UV 0,27<br />

IRSST<br />

283-1<br />

Open cassette sampl<strong>in</strong>g<br />

The sampl<strong>in</strong>g device must be refrigerated be<strong>for</strong>e and after sampl<strong>in</strong>g.<br />

Glycer<strong>in</strong> (mist)<br />

56-81-5<br />

10 SKC 225-8-01-1 or 225-8-04 polyv<strong>in</strong>yl 1,5 180 Grav 25 4,9 IRSST<br />

48-1<br />

chloride filter<br />

902 PVC filter-37<br />

914 PVC filter-25<br />

Additional <strong>in</strong><strong>for</strong>mation is available <strong>in</strong> Info-Labo 91-03. The weight measurement<br />

method <strong>for</strong> dusts is by def<strong>in</strong>ition non-specific.<br />

Glycidol<br />

556-52-5<br />

76 Activated charcoal tube 100/50 mg<br />

0,01-1 100 GC-FID<br />

NIOSH<br />

1608<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Gra<strong>in</strong> dust (oat, wheat,<br />

barley)<br />

4 Pt Polyv<strong>in</strong>yl chloride filter with Accu-Cap. 1,5 180 Grav 25 4,9 IRSST<br />

48-1<br />

910 PVC filter-37 with Accu-Cap<br />

<strong>Sampl<strong>in</strong>g</strong> of respirable dusts is also possible by us<strong>in</strong>g <strong>the</strong> flow rate appropriate to<br />

<strong>the</strong> cyclone used.<br />

Additional <strong>in</strong><strong>for</strong>mation is available <strong>in</strong> Info-Labo 91-03. The weight measurement<br />

method <strong>for</strong> dusts is by def<strong>in</strong>ition non-specific.<br />

Graphite (all <strong>for</strong>ms<br />

except fibers)<br />

7782-42-5<br />

2 Pr SKC 225-8-01-1 or 225-8-04 polyv<strong>in</strong>yl 1,7 180 Grav 25 4,9 IRSST<br />

48-1<br />

chloride filter<br />

(nylon)<br />

902<br />

914<br />

PVC filter-37<br />

PVC filter-25<br />

2,75<br />

(GS3)<br />

997 PVC filter-37, 3 parts<br />

Additional <strong>in</strong><strong>for</strong>mation is available <strong>in</strong> Info-Labo 91-03. The weight measurement<br />

method <strong>for</strong> dusts is by def<strong>in</strong>ition non-specific.<br />

Gypsum<br />

13397-24-5<br />

10 Pt SKC 225-8-01-1 or 225-8-04 polyv<strong>in</strong>yl 1,5 180 Grav 25 4,9 IRSST<br />

48-1<br />

chloride filter<br />

902 PVC filter-37<br />

914 PVC filter-25<br />

Additional <strong>in</strong><strong>for</strong>mation is available <strong>in</strong> Info-Labo 91-03. The weight measurement<br />

method <strong>for</strong> dusts is by def<strong>in</strong>ition non-specific.