ROHS Substances table<br />

126<br />

ROHS Name<br />

CAS<br />

TWAEV<br />

STEV<br />

Ceil<strong>in</strong>g<br />

(mg/m³)<br />

Notes<br />

<strong>Sampl<strong>in</strong>g</strong><br />

Device<br />

Flow<br />

L/m<strong>in</strong><br />

Volume<br />

TWAEV<br />

STEV<br />

(L)<br />

Pr<strong>in</strong>ciple<br />

MRV<br />

µg<br />

CVa<br />

(%)<br />

#<br />

meth.<br />

Remarks<br />

Tributyl phosphate<br />

126-73-8<br />

2,2 Mixed cellulose ester filter<br />

1-3 100 GC-FPD<br />

NIOSH<br />

5034<br />

Accord<strong>in</strong>g to NIOSH 5034, two mixed cellulose ester filters <strong>in</strong> series can be used<br />

<strong>in</strong> <strong>the</strong> case where <strong>the</strong> temperature of <strong>the</strong> sampl<strong>in</strong>g site exceeds 23°C. Contact<br />

<strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Trichloroacetic acid<br />

76-03-9<br />

6,7 Silica gel tube 100/50 mg<br />

0,2 10 HPLC-UV<br />

OSHA<br />

PV2017<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

1,2,4-Trichlorobenzene<br />

120-82-1<br />

--<br />

--<br />

37<br />

RP Polytetrafluorocarbon (teflon) filter <strong>in</strong><br />

0,01- 10 GC-ECD<br />

NIOSH<br />

5517<br />

series with an XAD-2 tube<br />

0,2<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

1,1,2-Trichloroethane<br />

79-00-5<br />

55 Pc SKC 226-01 activated charcoal tube<br />

Max: 10 GC-FID 22<br />

IRSST<br />

102-1<br />

2120 Activated charcoal 100/50 mg<br />

0,2<br />

Trichloroethylene<br />

79-01-6<br />

269<br />

1070<br />

SKC 226-01 activated charcoal tube<br />

2120 Activated charcoal 100/50 mg<br />

Max:<br />

0,2<br />

10<br />

3<br />

GC-FID<br />

58 0,8<br />

IRSST<br />

75-3<br />

The analysis can be done by gas chromatography coupled with mass<br />

spectrometry (GC-MS, IRSST method #369); <strong>in</strong> this case <strong>the</strong> analytical<br />

uncerta<strong>in</strong>ty (CVa) is 0.78%.<br />

Trichloroethylene<br />

79-01-6<br />

269<br />

1070<br />

3M 3500 organic vapour monitor<br />

2695 Passive dosimeter<br />

0,0311 GC-FID 58 0,8<br />

IRSST<br />

75-3<br />

For <strong>the</strong> monitors, <strong>the</strong> flow must be considered as be<strong>in</strong>g a sampl<strong>in</strong>g rate.<br />

Accord<strong>in</strong>g to <strong>the</strong> data from 3M, <strong>the</strong> precision (CVsampl<strong>in</strong>g) of <strong>the</strong> sampl<strong>in</strong>g rate is<br />

0.6%. Refer to <strong>the</strong> 3M passive monitor guide on <strong>the</strong> IRSST's Web site.<br />

Trichlorofluoromethane<br />

75-69-4<br />

--<br />

--<br />

5620<br />

RP Activated charcoal tube 400/200 mg<br />

Max: 4 GC-FID<br />

NIOSH<br />

1006<br />

0,05<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Trichloronaphthalene<br />

1321-65-9<br />

5 Pc OVS-2 tube with XAD-2 and glass fiber 1 100 GC-ECD<br />

OSHA<br />

IMIS2483<br />

filter<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

1,2,3-Trichloropropane<br />

96-18-4<br />

60 Pc Activated charcoal tube 100/50 mg<br />

0,01- 10 GC-FID<br />

NIOSH<br />

1003<br />

0,2<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

1,1,2-Trichloro-1,2,2-<br />

trifluoroethane<br />

76-13-1<br />

7670<br />

9590<br />

SKC 226-09 activated charcoal tube<br />

2121 Activated charcoal 400/200 mg<br />

0,2 5 GC-FID 2 1,4 IRSST<br />

191-1<br />

Specific desorption must be carried out <strong>for</strong> this substance. Freon 113. However,<br />

<strong>the</strong> simultaneous sampl<strong>in</strong>g and analysis of chlorodifluoromethane (Freon 22) is<br />

possible.