Sampling Guide for Air Contaminants in the Workplace - Irsst
Sampling Guide for Air Contaminants in the Workplace - Irsst
Sampling Guide for Air Contaminants in the Workplace - Irsst
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
ROHS Substances table<br />
126<br />
ROHS Name<br />
CAS<br />
TWAEV<br />
STEV<br />
Ceil<strong>in</strong>g<br />
(mg/m³)<br />
Notes<br />
<strong>Sampl<strong>in</strong>g</strong><br />
Device<br />
Flow<br />
L/m<strong>in</strong><br />
Volume<br />
TWAEV<br />
STEV<br />
(L)<br />
Pr<strong>in</strong>ciple<br />
MRV<br />
µg<br />
CVa<br />
(%)<br />
#<br />
meth.<br />
Remarks<br />
Tributyl phosphate<br />
126-73-8<br />
2,2 Mixed cellulose ester filter<br />
1-3 100 GC-FPD<br />
NIOSH<br />
5034<br />
Accord<strong>in</strong>g to NIOSH 5034, two mixed cellulose ester filters <strong>in</strong> series can be used<br />
<strong>in</strong> <strong>the</strong> case where <strong>the</strong> temperature of <strong>the</strong> sampl<strong>in</strong>g site exceeds 23°C. Contact<br />
<strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Trichloroacetic acid<br />
76-03-9<br />
6,7 Silica gel tube 100/50 mg<br />
0,2 10 HPLC-UV<br />
OSHA<br />
PV2017<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
1,2,4-Trichlorobenzene<br />
120-82-1<br />
--<br />
--<br />
37<br />
RP Polytetrafluorocarbon (teflon) filter <strong>in</strong><br />
0,01- 10 GC-ECD<br />
NIOSH<br />
5517<br />
series with an XAD-2 tube<br />
0,2<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
1,1,2-Trichloroethane<br />
79-00-5<br />
55 Pc SKC 226-01 activated charcoal tube<br />
Max: 10 GC-FID 22<br />
IRSST<br />
102-1<br />
2120 Activated charcoal 100/50 mg<br />
0,2<br />
Trichloroethylene<br />
79-01-6<br />
269<br />
1070<br />
SKC 226-01 activated charcoal tube<br />
2120 Activated charcoal 100/50 mg<br />
Max:<br />
0,2<br />
10<br />
3<br />
GC-FID<br />
58 0,8<br />
IRSST<br />
75-3<br />
The analysis can be done by gas chromatography coupled with mass<br />
spectrometry (GC-MS, IRSST method #369); <strong>in</strong> this case <strong>the</strong> analytical<br />
uncerta<strong>in</strong>ty (CVa) is 0.78%.<br />
Trichloroethylene<br />
79-01-6<br />
269<br />
1070<br />
3M 3500 organic vapour monitor<br />
2695 Passive dosimeter<br />
0,0311 GC-FID 58 0,8<br />
IRSST<br />
75-3<br />
For <strong>the</strong> monitors, <strong>the</strong> flow must be considered as be<strong>in</strong>g a sampl<strong>in</strong>g rate.<br />
Accord<strong>in</strong>g to <strong>the</strong> data from 3M, <strong>the</strong> precision (CVsampl<strong>in</strong>g) of <strong>the</strong> sampl<strong>in</strong>g rate is<br />
0.6%. Refer to <strong>the</strong> 3M passive monitor guide on <strong>the</strong> IRSST's Web site.<br />
Trichlorofluoromethane<br />
75-69-4<br />
--<br />
--<br />
5620<br />
RP Activated charcoal tube 400/200 mg<br />
Max: 4 GC-FID<br />
NIOSH<br />
1006<br />
0,05<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Trichloronaphthalene<br />
1321-65-9<br />
5 Pc OVS-2 tube with XAD-2 and glass fiber 1 100 GC-ECD<br />
OSHA<br />
IMIS2483<br />
filter<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
1,2,3-Trichloropropane<br />
96-18-4<br />
60 Pc Activated charcoal tube 100/50 mg<br />
0,01- 10 GC-FID<br />
NIOSH<br />
1003<br />
0,2<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
1,1,2-Trichloro-1,2,2-<br />
trifluoroethane<br />
76-13-1<br />
7670<br />
9590<br />
SKC 226-09 activated charcoal tube<br />
2121 Activated charcoal 400/200 mg<br />
0,2 5 GC-FID 2 1,4 IRSST<br />
191-1<br />
Specific desorption must be carried out <strong>for</strong> this substance. Freon 113. However,<br />
<strong>the</strong> simultaneous sampl<strong>in</strong>g and analysis of chlorodifluoromethane (Freon 22) is<br />
possible.