Sampling Guide for Air Contaminants in the Workplace - Irsst
Sampling Guide for Air Contaminants in the Workplace - Irsst
Sampling Guide for Air Contaminants in the Workplace - Irsst
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
ROHS Substances table<br />
114<br />
ROHS Name<br />
CAS<br />
TWAEV<br />
STEV<br />
Ceil<strong>in</strong>g<br />
(mg/m³)<br />
Notes<br />
<strong>Sampl<strong>in</strong>g</strong><br />
Device<br />
Flow<br />
L/m<strong>in</strong><br />
Volume<br />
TWAEV<br />
STEV<br />
(L)<br />
Pr<strong>in</strong>ciple<br />
MRV<br />
µg<br />
CVa<br />
(%)<br />
#<br />
meth.<br />
Remarks<br />
Propylene oxide<br />
75-56-9<br />
48 C2<br />
RP<br />
EM<br />
Activated charcoal tube 100/50 mg<br />
0,01-<br />
0,2<br />
5 GC-FID<br />
NIOSH<br />
1612<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Pyrethrum<br />
8003-34-7<br />
5 OVS-2 tube with XAD-2 and glass fiber 1 60 GC-ECD<br />
OSHA<br />
70<br />
filter<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Pyrid<strong>in</strong>e<br />
110-86-1<br />
16 SKC 226-01 activated charcoal tube<br />
Max: 5 GC-NPD 4<br />
IRSST<br />
199-1<br />
2120 Activated charcoal 100/50 mg<br />
1,0<br />
Pyrid<strong>in</strong>e must be sampled specifically due to <strong>the</strong> sampl<strong>in</strong>g device used and a<br />
specific desorption solvent.<br />
Resorc<strong>in</strong>ol<br />
108-46-3<br />
45<br />
90<br />
Versatile OVS-7 tube with XAD-7 and a<br />
glass fiber filter<br />
0,05-<br />
0,1<br />
24 GC-FID<br />
NIOSH<br />
5701<br />
Keeps <strong>for</strong> 30 days at 5°C protected from light. Contact <strong>the</strong> IRSST be<strong>for</strong>e<br />
sampl<strong>in</strong>g.<br />
Rhodium [7440-16-6],<br />
Metal and <strong>in</strong>soluble<br />
compounds (as Rh)<br />
7440-16-6<br />
0,1 Mixed cellulose ester filter<br />
1-5 480 ICP-MS<br />
ASTM<br />
D7439-08<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Rhodium [7440-16-6],<br />
Soluble compounds (as<br />
Rh)<br />
7440-16-6<br />
0,001 Mixed cellulose ester filter<br />
1-5 480 ICP-MS<br />
ASTM<br />
D7439-08<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Ronnel<br />
299-84-3<br />
10 OVS-2 tube with XAD-2 and glass fiber 0,2-1 60 GC-FPD<br />
NIOSH<br />
5600<br />
filter<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Some phosphates may cause <strong>in</strong>terference dur<strong>in</strong>g <strong>the</strong> analysis.<br />
Ros<strong>in</strong> core solder<br />
pyrolysis products (as<br />
Formaldehyde)<br />
8050-09-7<br />
0,1 S<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
No support<strong>in</strong>g reference is suggested <strong>for</strong> this substance.<br />
Rotenone<br />
83-79-4<br />
5 Polytetrafluorocarbon (teflon) filter<br />
1-4 100 HPLC-UV<br />
NIOSH<br />
5007<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.