ROHS Substances table<br />

114<br />

ROHS Name<br />

CAS<br />

TWAEV<br />

STEV<br />

Ceil<strong>in</strong>g<br />

(mg/m³)<br />

Notes<br />

<strong>Sampl<strong>in</strong>g</strong><br />

Device<br />

Flow<br />

L/m<strong>in</strong><br />

Volume<br />

TWAEV<br />

STEV<br />

(L)<br />

Pr<strong>in</strong>ciple<br />

MRV<br />

µg<br />

CVa<br />

(%)<br />

#<br />

meth.<br />

Remarks<br />

Propylene oxide<br />

75-56-9<br />

48 C2<br />

RP<br />

EM<br />

Activated charcoal tube 100/50 mg<br />

0,01-<br />

0,2<br />

5 GC-FID<br />

NIOSH<br />

1612<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Pyrethrum<br />

8003-34-7<br />

5 OVS-2 tube with XAD-2 and glass fiber 1 60 GC-ECD<br />

OSHA<br />

70<br />

filter<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Pyrid<strong>in</strong>e<br />

110-86-1<br />

16 SKC 226-01 activated charcoal tube<br />

Max: 5 GC-NPD 4<br />

IRSST<br />

199-1<br />

2120 Activated charcoal 100/50 mg<br />

1,0<br />

Pyrid<strong>in</strong>e must be sampled specifically due to <strong>the</strong> sampl<strong>in</strong>g device used and a<br />

specific desorption solvent.<br />

Resorc<strong>in</strong>ol<br />

108-46-3<br />

45<br />

90<br />

Versatile OVS-7 tube with XAD-7 and a<br />

glass fiber filter<br />

0,05-<br />

0,1<br />

24 GC-FID<br />

NIOSH<br />

5701<br />

Keeps <strong>for</strong> 30 days at 5°C protected from light. Contact <strong>the</strong> IRSST be<strong>for</strong>e<br />

sampl<strong>in</strong>g.<br />

Rhodium [7440-16-6],<br />

Metal and <strong>in</strong>soluble<br />

compounds (as Rh)<br />

7440-16-6<br />

0,1 Mixed cellulose ester filter<br />

1-5 480 ICP-MS<br />

ASTM<br />

D7439-08<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Rhodium [7440-16-6],<br />

Soluble compounds (as<br />

Rh)<br />

7440-16-6<br />

0,001 Mixed cellulose ester filter<br />

1-5 480 ICP-MS<br />

ASTM<br />

D7439-08<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Ronnel<br />

299-84-3<br />

10 OVS-2 tube with XAD-2 and glass fiber 0,2-1 60 GC-FPD<br />

NIOSH<br />

5600<br />

filter<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Some phosphates may cause <strong>in</strong>terference dur<strong>in</strong>g <strong>the</strong> analysis.<br />

Ros<strong>in</strong> core solder<br />

pyrolysis products (as<br />

Formaldehyde)<br />

8050-09-7<br />

0,1 S<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

No support<strong>in</strong>g reference is suggested <strong>for</strong> this substance.<br />

Rotenone<br />

83-79-4<br />

5 Polytetrafluorocarbon (teflon) filter<br />

1-4 100 HPLC-UV<br />

NIOSH<br />

5007<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.