ROHS Substances table<br />

92<br />

ROHS Name<br />

CAS<br />

TWAEV<br />

STEV<br />

Ceil<strong>in</strong>g<br />

(mg/m³)<br />

Notes<br />

<strong>Sampl<strong>in</strong>g</strong><br />

Device<br />

Flow<br />

L/m<strong>in</strong><br />

Volume<br />

TWAEV<br />

STEV<br />

(L)<br />

Pr<strong>in</strong>ciple<br />

MRV<br />

µg<br />

CVa<br />

(%)<br />

#<br />

meth.<br />

Remarks<br />

Limestone<br />

1317-65-3<br />

10 Pt SKC 225-8-01-1 or 225-8-04 polyv<strong>in</strong>yl 1,5 180 Grav 25 4,9 IRSST<br />

48-1<br />

chloride filter<br />

902 PVC filter-37<br />

914 PVC filter-25<br />

Additional <strong>in</strong><strong>for</strong>mation is available <strong>in</strong> Info-Labo 91-03. The weight measurement<br />

method <strong>for</strong> dusts is by def<strong>in</strong>ition non-specific.<br />

L<strong>in</strong>dane<br />

58-89-9<br />

0,5 Pc Glass fiber filter <strong>in</strong> series with a glass 0,2-1 240 GC-ECD<br />

NIOSH<br />

5502<br />

midget imp<strong>in</strong>ger conta<strong>in</strong><strong>in</strong>g 15 mL of<br />

isooctane<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Lithium hydride<br />

7580-67-8<br />

0,025 Mixed cellulose ester filter<br />

2 960 FAAS<br />

OSHA<br />

ID121<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Magnesite<br />

546-93-0<br />

10 Pt SKC 225-8-01-1 or 225-8-04 polyv<strong>in</strong>yl 1,5 180 Grav 25 4,9 IRSST<br />

48-1<br />

chloride filter<br />

902 PVC filter-37<br />

914 PVC filter-25<br />

Additional <strong>in</strong><strong>for</strong>mation is available <strong>in</strong> Info-Labo 91-03. The weight measurement<br />

method <strong>for</strong> dusts is by def<strong>in</strong>ition non-specific.<br />

Magnesium oxide fume<br />

(as Mg)<br />

1309-48-4<br />

10 Mixed cellulose ester filter, 0.8µm, 25 and 1,5 180 ICP-MS 2 4,06 IRSST<br />

362<br />

37 mm.<br />

905 MCE filter-37<br />

915 MCE filter-25<br />

Cassettes 913 or 916, whose filters are preweighed, can also be used. For<br />

surface wipe sampl<strong>in</strong>g, contact Laboratory Customer Service.<br />

The analytical results are expressed as total magnesium.<br />

Malathion<br />

121-75-5<br />

10 Pc Supelco ORBO 49P tube, # 2-350<br />

0,2-1 60 GC-NPD 15<br />

IRSST<br />

228-1<br />

2180 Orbo 49P<br />

Malathion must be specifically sampled due to <strong>the</strong> sampl<strong>in</strong>g device and a specific<br />

desorption solvent.<br />

Maleic anhydride<br />

108-31-6<br />

1 Glass fiber filters impregnated with<br />

0,5 60 HPLC-UV<br />

OSHA<br />

86<br />

veratrylam<strong>in</strong>e.<br />

The samples must be stored <strong>in</strong> <strong>the</strong> refrigerator until analysis. Contact <strong>the</strong> IRSST<br />

be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Isocyanates, hydrochloric acid and aldehydes can cause <strong>in</strong>terference dur<strong>in</strong>g<br />

sampl<strong>in</strong>g.<br />

Manganese [7439-96-5]<br />

(as Mn), Dust and<br />

compounds<br />

7439-96-5<br />

5 Mixed cellulose ester filter, 0.8µm, 25 and<br />

37 mm.<br />

1,5 180<br />

22,5<br />

ICP-MS 1 3,16<br />

905 MCE filter-37<br />

915 MCE filter-25<br />

IRSST<br />

362<br />

Cassettes 913 or 916, whose filters are preweighed, can also be used. For<br />

surface wipe sampl<strong>in</strong>g, contact Laboratory Customer Service.<br />

The analytical results are expressed as total manganese. A stoichiometric factor<br />

must be applied.