ROHS Substances table<br />

70<br />

ROHS Name<br />

CAS<br />

TWAEV<br />

STEV<br />

Ceil<strong>in</strong>g<br />

(mg/m³)<br />

Notes<br />

<strong>Sampl<strong>in</strong>g</strong><br />

Device<br />

Flow<br />

L/m<strong>in</strong><br />

Volume<br />

TWAEV<br />

STEV<br />

(L)<br />

Pr<strong>in</strong>ciple<br />

MRV<br />

µg<br />

CVa<br />

(%)<br />

#<br />

meth.<br />

Remarks<br />

Dicrotophos<br />

141-66-2<br />

0,25 Pc OVS-2 tube with XAD-2 and glass fiber 0,2-1 240 GC-FPD<br />

NIOSH<br />

5600<br />

filter<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Some phosphates may cause <strong>in</strong>terference dur<strong>in</strong>g <strong>the</strong> analysis.<br />

Dicyclopentadiene<br />

77-73-6<br />

27 SKC 226-01 activated charcoal tube<br />

Max: 20 GC-FID 30 4,0 IRSST<br />

242-1<br />

2120 Activated charcoal 100/50 mg<br />

0,2<br />

Dicyclopentadienyl iron<br />

102-54-5<br />

10<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

IRSST method 362 is <strong>for</strong> iron and can be adapted to iron dicyclopentadiene.<br />

IRSST method 48-1 (gravimetric analysis) can also be used, given <strong>the</strong> standard<br />

of 10 mg/m³.<br />

Dieldr<strong>in</strong><br />

60-57-1<br />

0,25 Pc OVS-2 tube with XAD-2 with glass fiber 1 480 GC-ECD<br />

OSHA<br />

67<br />

filter<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Diethanolam<strong>in</strong>e<br />

111-42-2<br />

13 Pc Impregnated Millipore AP4003705 glass 1 15 HPLC-MS 10<br />

IRSST<br />

363<br />

fiber filter<br />

955 Impregned FGF<br />

Anil<strong>in</strong>e, diethanolam<strong>in</strong>e, dimethylam<strong>in</strong>e, ethanolam<strong>in</strong>e, isopropylam<strong>in</strong>e,<br />

methylam<strong>in</strong>e and morphol<strong>in</strong>e can be sampled at <strong>the</strong> same time.<br />

Diethyl e<strong>the</strong>r<br />

60-29-7<br />

1210<br />

1520<br />

SKC 226-01 activated charcoal tube<br />

2120 Activated charcoal 100/50 mg<br />

Max:<br />

0,2<br />

3<br />

3<br />

GC-FID<br />

72 4,0<br />

IRSST<br />

28-1<br />

The analysis can be done by gas chromatography coupled with mass<br />

spectrometry (GC-MS, IRSST method #369); <strong>in</strong> this case <strong>the</strong> analytical<br />

uncerta<strong>in</strong>ty (CVa) is 0.67%.<br />

Diethyl ketone<br />

96-22-0<br />

705 Activated charcoal tube 100/50 mg<br />

0,2 10 GC-FID<br />

OSHA<br />

07<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Diethyl phthalate<br />

84-66-2<br />

5 Whatman 7188 003 cellulose nitrate filter 1,0 30 HPLC-UV 8<br />

IRSST<br />

310-1<br />

912 CN filter-37<br />

Store <strong>in</strong> refrigerator after sampl<strong>in</strong>g.<br />

Diethylam<strong>in</strong>e<br />

109-89-7<br />

15<br />

45<br />

Pc XAD-7 tube impregnated with 10% 7- 0,2 10 HPLC-UV<br />

chloro-4-nitrobenzo-2-oxa-1,3-diazole<br />

3<br />

OSHA<br />

IMIS0910<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

2-Diethylam<strong>in</strong>oethanol<br />

100-37-8<br />

48 Pc Silica gel tube 300/150 mg<br />

0,2 24 GC-FID<br />

NIOSH<br />

2007<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.