ROHS Substances table<br />
82<br />
ROHS Name<br />
CAS<br />
TWAEV<br />
STEV<br />
Ceil<strong>in</strong>g<br />
(mg/m³)<br />
Notes<br />
<strong>Sampl<strong>in</strong>g</strong><br />
Device<br />
Flow<br />
L/m<strong>in</strong><br />
Volume<br />
TWAEV<br />
STEV<br />
(L)<br />
Pr<strong>in</strong>ciple<br />
MRV<br />
µg<br />
CVa<br />
(%)<br />
#<br />
meth.<br />
Remarks<br />
Formaldehyde<br />
50-00-0<br />
--<br />
--<br />
3<br />
C2<br />
RP<br />
EM<br />
Supelco 2-0257 Orbo 23 tube<br />
2186 Orbo 23 120/60 mg<br />
0,1 GC-MS 3<br />
10 IRSST<br />
329-1<br />
Be<strong>for</strong>e and after sampl<strong>in</strong>g, tubes must be stored <strong>in</strong> a freezer. Additional<br />
<strong>in</strong><strong>for</strong>mation is also available <strong>in</strong> laboratory customer service communiqué SAC-<br />
Labo 2006-08.<br />
Eleven aldehydes are determ<strong>in</strong>ed simultaneously: acetaldehyde,<br />
isobutyraldehyde, isovaleraldehyde, propionaldehyde, butyraldehyde, furfural,<br />
heptanal, hexanal, valeraldehyde, acrole<strong>in</strong>e and <strong>for</strong>maldehyde. This method must<br />
not be used <strong>for</strong> <strong>the</strong> specific evaluation of <strong>for</strong>maldehyde; <strong>the</strong> methods to be used<br />
<strong>in</strong> this case are 295-1 and 357-1.<br />
Formaldehyde<br />
50-00-0<br />
--<br />
--<br />
3<br />
C2<br />
RP<br />
EM<br />
XAD-2 tube impregnated with HMP<br />
2188 XAD-2 120/60 mg impregnated with HMP<br />
Max:<br />
0,1<br />
25 GC-NPD 2 4,5 IRSST<br />
295-1<br />
Formaldehyde must be specifically sampled due to <strong>the</strong> sampl<strong>in</strong>g device used and<br />
a specific desorption solvent. The tubes must be stored <strong>in</strong> <strong>the</strong> freezer be<strong>for</strong>e and<br />
after sampl<strong>in</strong>g. Additional <strong>in</strong><strong>for</strong>mation is also available <strong>in</strong> laboratory customer<br />
service communiqué SAC-Labo 2006-08.<br />
Formaldehyde<br />
50-00-0<br />
--<br />
--<br />
3<br />
C2<br />
RP<br />
EM<br />
DRI-PAD<br />
IRSST<br />
39-A<br />
Refer to <strong>the</strong> user's guide accompany<strong>in</strong>g <strong>the</strong> <strong>in</strong>strument. Additional <strong>in</strong><strong>for</strong>mation is<br />
also available <strong>in</strong> laboratory customer service communiqué SAC-Labo 2006-08.<br />
The m<strong>in</strong>imum reported value is 0.15 mg/m³ (0.12 ppm). The reference method<br />
corresponds to calibration of <strong>the</strong> direct-read<strong>in</strong>g <strong>in</strong>strument (DRI). Formaldehyde<br />
quantified <strong>in</strong> <strong>the</strong> field with a DRI.<br />
Formaldehyde<br />
50-00-0<br />
--<br />
--<br />
3<br />
C2<br />
RP<br />
EM<br />
SKC #500-100 UMEX-100 passive<br />
sampler<br />
6100 Passive sampler<br />
0,0286 HPLC-UV 0,21<br />
IRSST<br />
357-1<br />
Keep <strong>in</strong> freezer be<strong>for</strong>e and after sampl<strong>in</strong>g. For monitors, flow must be<br />
considered as be<strong>in</strong>g a sampl<strong>in</strong>g rate. Additional <strong>in</strong><strong>for</strong>mation is also available <strong>in</strong><br />
<strong>the</strong> laboratory services communiqué SAC-Labo 2006-08.<br />
Stable <strong>for</strong> 3 weeks after sampl<strong>in</strong>g.<br />
Formamide<br />
75-12-7<br />
18 Pc Silica gel tube 150/75 mg<br />
0,1 10 GC-FID<br />
OSHA<br />
IMIS1292<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />
Formic acid<br />
64-18-6<br />
9,4<br />
19<br />
PTFE filter with treated silica gel tube<br />
400/200 mg<br />
0,05-<br />
0,2<br />
24<br />
3<br />
IC-CD<br />
NIOSH<br />
2011<br />
Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g. The sample is stable <strong>for</strong> 1 week at 25°C.<br />
Furfural<br />
98-01-1<br />
7,9 Pc Supelco 2-0257 Orbo 23 tube<br />
0,1 10 GC-MS 0,11<br />
IRSST<br />
328-1<br />
2186 Orbo 23 120/60 mg<br />
Be<strong>for</strong>e and after sampl<strong>in</strong>g, tubes must be stored <strong>in</strong> a freezer.<br />
Eleven aldehydes are determ<strong>in</strong>ed simultaneously: acetaldehyde,<br />
isobutyraldehyde, isovaleraldehyde, propionaldehyde, butyraldehyde, furfural,<br />
heptanal, hexanal, valeraldehyde, acrole<strong>in</strong> and <strong>for</strong>maldehyde. This method must<br />
not be used <strong>for</strong> <strong>the</strong> specific evaluation of <strong>for</strong>maldehyde; <strong>the</strong> methods to be used<br />
<strong>in</strong> this case are 295-1 and 357-1.<br />
Furfuryl alcohol<br />
98-00-0<br />
40<br />
60<br />
Pc Porapak Q tube #SKC 226-115<br />
Max: 6<br />
2162 Porapak Q 150/75 mg<br />
0,05 0,75<br />
GC-FID<br />
4,7 4,0<br />
IRSST<br />
87-2<br />
Furfuryl alcohol must be sampled specifically due to <strong>the</strong> sampl<strong>in</strong>g device used<br />