Sampling Guide for Air Contaminants in the Workplace - Irsst
Sampling Guide for Air Contaminants in the Workplace - Irsst
Sampling Guide for Air Contaminants in the Workplace - Irsst
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
IRSST – <strong>Sampl<strong>in</strong>g</strong> <strong>Guide</strong> <strong>for</strong> <strong>Air</strong> <strong>Contam<strong>in</strong>ants</strong> <strong>in</strong> <strong>the</strong> <strong>Workplace</strong> 141<br />
Surface identification kits<br />
Components of surface identification kits<br />
MRV<br />
µg/media<br />
IRSST<br />
no.<br />
Chromium VI<br />
Cyanide<br />
- Clear bottle conta<strong>in</strong><strong>in</strong>g a solution of dilute sulfuric acid, 1 N H 2 SO 4<br />
- Brown bottle conta<strong>in</strong><strong>in</strong>g a solution of 1% diphenylcarbazide (DPC)<br />
5 disposable droppers<br />
- paper towels<br />
- one pair of 100% nitrile gloves<br />
- Kit user's guide<br />
- bottle #1 conta<strong>in</strong><strong>in</strong>g 0.1 N NaOH<br />
- bottle #2 conta<strong>in</strong><strong>in</strong>g palladium dimethylglyoxime <strong>in</strong> 3 N KOH<br />
- bottle #3 conta<strong>in</strong><strong>in</strong>g nickel chloride and ammonium chloride <strong>in</strong> water<br />
- paper towels<br />
- one pair of 100% nitrile gloves<br />
- Kit user's guide<br />
0.1 2625<br />
25 3020<br />
Metals<br />
- 5 petri dishes, each conta<strong>in</strong><strong>in</strong>g an MCE filter 37 mm 0.8 µm numbered<br />
- 5 templates, 10 cm by 10 cm<br />
- 1 bottle of dem<strong>in</strong>eralized water<br />
- 5 pairs of 100% nitrile gloves<br />
- Kit user's guide<br />
Refer to <strong>the</strong><br />
green table<br />
of<br />
substances<br />
<strong>in</strong> <strong>the</strong><br />
guide 8<br />
- 5 wet wipes<br />
Beryllium - 5 templates, 10 cm by 10 cm<br />
0.05<br />
- 5 polypropylene conta<strong>in</strong>ers, numbered<br />
- 5 pairs of 100% nitrile gloves<br />
Lead - Kit user's guide<br />
0.5<br />
Aliphatic<br />
isocyanates<br />
(HDI)<br />
Aromatic<br />
isocyanates<br />
(MDI and TDI)<br />
Mycological<br />
structures<br />
Mycological<br />
structures and/or<br />
identification by<br />
growth<br />
- 1 bag conta<strong>in</strong><strong>in</strong>g 25 impregnated swabs<br />
- 1 bottle conta<strong>in</strong><strong>in</strong>g <strong>the</strong> develop<strong>in</strong>g solution <strong>for</strong> HDI with <strong>the</strong> sampl<strong>in</strong>g<br />
protocol on <strong>the</strong> bottle<br />
- 1 pair of 100% nitrile gloves<br />
- 1 bag conta<strong>in</strong><strong>in</strong>g 25 impregnated swabs<br />
- 1 bottle conta<strong>in</strong><strong>in</strong>g <strong>the</strong> develop<strong>in</strong>g solution <strong>for</strong> MDI and TDI with <strong>the</strong><br />
sampl<strong>in</strong>g protocol on <strong>the</strong> bottle<br />
- 1 pair of 100% nitrile gloves<br />
Slide<br />
- Numbered Bio-tape <strong>in</strong> a case<br />
(See protocole de prélèvement)<br />
Sponge<br />
- 1 plastic bag consist<strong>in</strong>g of 2 sections, with one section conta<strong>in</strong><strong>in</strong>g<br />
gloves and <strong>the</strong> sponge bag<br />
- The second section of <strong>the</strong> numbered bag is used <strong>for</strong> shipp<strong>in</strong>g <strong>the</strong> sponge<br />
to <strong>the</strong> laboratory<br />
3070<br />
3090<br />
3050<br />
3060<br />
5585<br />
5540<br />
Mould<br />
identification by<br />
growth<br />
Identification of<br />
bacteria by<br />
growth<br />
- Swab (<strong>in</strong>dividually)<br />
- Petri dish conta<strong>in</strong><strong>in</strong>g Malt <strong>for</strong> moulds<br />
- Swab (<strong>in</strong>dividually)<br />
- Petri dish conta<strong>in</strong><strong>in</strong>g TSA <strong>for</strong> bacteria<br />
5575<br />
5570<br />
5575<br />
5560<br />
8 The MRV of metals on media (µg/media) are equivalent to those documented <strong>for</strong> <strong>the</strong> correspond<strong>in</strong>g analytical<br />
method <strong>in</strong> <strong>the</strong> air (µg/filter).