ROHS Substances table<br />

97<br />

ROHS Name<br />

CAS<br />

TWAEV<br />

STEV<br />

Ceil<strong>in</strong>g<br />

(mg/m³)<br />

Notes<br />

<strong>Sampl<strong>in</strong>g</strong><br />

Device<br />

Flow<br />

L/m<strong>in</strong><br />

Volume<br />

TWAEV<br />

STEV<br />

(L)<br />

Pr<strong>in</strong>ciple<br />

MRV<br />

µg<br />

CVa<br />

(%)<br />

#<br />

meth.<br />

Remarks<br />

Methyl ethyl ketone<br />

(MEK)<br />

78-93-3<br />

150<br />

300<br />

3M 3500 organic vapour monitor<br />

2695 Passive dosimeter<br />

0,0363 GC-FID 30 6,0<br />

IRSST<br />

25-3<br />

For <strong>the</strong> monitors, <strong>the</strong> flow must be considered as be<strong>in</strong>g a sampl<strong>in</strong>g rate.<br />

Accord<strong>in</strong>g to <strong>the</strong> data from 3M, <strong>the</strong> precision (CVsampl<strong>in</strong>g) of <strong>the</strong> sampl<strong>in</strong>g rate is<br />

2.5%. Refer to <strong>the</strong> 3M passive monitor guide on <strong>the</strong> IRSST's Web site.<br />

Methyl ethyl ketone<br />

(MEK)<br />

78-93-3<br />

150<br />

300<br />

SKC 226-81 Anasorb 747 tube<br />

2190 Anasorb 747 140/70 mg<br />

Max:<br />

0,2<br />

10<br />

3<br />

GC-FID<br />

30 6,0<br />

IRSST<br />

25-3<br />

An activated charcoal tube 100/50 mg (#2120) may be used if <strong>the</strong> samples are<br />

refrigerated immediately after sampl<strong>in</strong>g of a maximum duration of 15 m<strong>in</strong>utes.<br />

This alternative is recommended if o<strong>the</strong>r organic substances must be analyzed<br />

simultaneously on <strong>the</strong> same sample, only if <strong>the</strong> risk of underestimat<strong>in</strong>g <strong>the</strong><br />

concentration of methyl ethyl ketone is assumed by <strong>the</strong> user. The analysis can be<br />

done by gas chromatography couple with mass spectrometry (CG-MS, IRSST<br />

method # 369); <strong>in</strong> this case <strong>the</strong> analytical uncerta<strong>in</strong>ty (CVa) is 1.7%.<br />

Methyl ethyl ketone<br />

peroxide<br />

1338-23-4<br />

--<br />

--<br />

1,5<br />

RP XAD-4 tube<br />

1 15 HPLC-UV<br />

NIOSH<br />

3508<br />

Substance is unstable at ambient temperature. Contact <strong>the</strong> IRSST be<strong>for</strong>e<br />

sampl<strong>in</strong>g.<br />

Methyl <strong>for</strong>mate<br />

107-31-3<br />

246<br />

368<br />

SKC 226-09 charcoal tube, 11 cm long,<br />

2121 Activated charcoal 400/200 mg<br />

0,2 3 GC-FID 40 4,0 IRSST<br />

349-1<br />

Methyl <strong>for</strong>mate must be sampled specifically because of <strong>the</strong> sampl<strong>in</strong>g device<br />

used and <strong>the</strong> specific desorption solvent.<br />

Methyl hydraz<strong>in</strong>e<br />

60-34-4<br />

--<br />

--<br />

0,38<br />

Pc<br />

C2<br />

RP<br />

EM<br />

Glass fritted tip imp<strong>in</strong>ger conta<strong>in</strong><strong>in</strong>g 15 mL<br />

of 0.1 M hydrochloric acid<br />

1,5 20 Colo<br />

NIOSH<br />

3510<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

O<strong>the</strong>r hydraz<strong>in</strong>es, stannous or ferrous ions, z<strong>in</strong>c, sulfur dioxide, hydrogen sulfide,<br />

halogens and oxygen (<strong>in</strong> <strong>the</strong> presence of Cu I) may cause <strong>in</strong>terference.<br />

Methyl iodide<br />

74-88-4<br />

12 Pc<br />

C2<br />

EM<br />

Activated charcoal tube 100/50mg<br />

0,01-1 50 GC-FID<br />

NIOSH<br />

1014<br />

Contact <strong>the</strong> IRSST be<strong>for</strong>e sampl<strong>in</strong>g.<br />

Methyl isoamyl ketone<br />

110-12-3<br />

234 SKC 226-01 activated charcoal tube<br />

Max: 10 GC-FID 10 3,5 IRSST<br />

265-2<br />

2120 Activated charcoal 100/50 mg<br />

0,2<br />

Methyl isobutyl ketone<br />

108-10-1<br />

205<br />

307<br />

3M 3500 organic vapour monitor<br />

2695 Passive dosimeter<br />

0,030 GC-FID 40 1,4<br />

IRSST<br />

132-3<br />

For <strong>the</strong> monitors, <strong>the</strong> flow must be considered as be<strong>in</strong>g a sampl<strong>in</strong>g rate.<br />

Accord<strong>in</strong>g to <strong>the</strong> data from 3M, <strong>the</strong> precision (CVsampl<strong>in</strong>g) of <strong>the</strong> sampl<strong>in</strong>g rate is<br />

1.3%. Refer to <strong>the</strong> 3M passive monitor guide on <strong>the</strong> IRSST's Web site.